Answers are grounded in this paper and cite their sources.
For accurate treatment planning, virtual surgical planning makes use of clinical data, image testing, plaster models of dentalarches, and clinical pictures. Plaster model scanning can be done in two ways: using an extraoral scanner or cone-beamcomputed tomography (CBCT).The aim of this study was to assess the accuracy digital dental stone models obtained using conebeam computed tomography and extraoral scanner. Materials and methods: The control group was the measurement performedon 20 plaster models by digital caliper. The same 20 models were scanned through extraoral scanner and CBCT in order tocompare the dimensional accuracy. Six measurements were performed on each model between reference points. Results: Therewas no statistically significant difference in dimensional accuracy between digital models obtained by CBCT scanning andextraoral scanning compared with digital caliber measurements with higher accuracy for extraoral scanned models. Conclusion:CBCT and extraoral scanning digitized models have acceptable dimentional accuracy.
No takes yet. Share an insight, caveat, or question.
Shaker et al. (2024) studied this question.