Key result
The Continuous AutoTransfusion System (C.A.T.S) reduced mean postoperative hospital stay (18 vs 25 days, P=0.014) and allogenic transfusions, with 30-day mortality of 12% vs 19% (P=0.199).
Why the study?
Does the Continuous AutoTransfusion System reduce allogenic blood transfusion and improve clinical outcomes in patients undergoing open abdominal aortic aneurysm repair?
Cohort (n=187)
Does the Continuous AutoTransfusion System reduce allogenic blood transfusion and improve clinical outcomes in patients undergoing open abdominal aortic aneurysm repair?
Absolute Event Rate: 12% vs 19%
p-value: p=.199
The use of a continuous autotransfusion system during open abdominal aortic aneurysm repair significantly reduces the need for allogenic blood transfusions and shortens hospital length of stay.
The use of the Continuous AutoTransfusion System (C.A.T.S; Fresenius Hemotechnology, Bad Homburg v.d.H., Germany), which conserves allogenic blood, is reported in 187 patients having abdominal aortic aneurysm repair during a 9-year period. Patients were allocated to C.A.T.S if a Haemovigilance technician was available. A mean of 685 mL of retrieved blood was reinfused in 101 patients receiving C.A.T.S; 61% required 2 U or less. All control patients required 3 U or more of allogenic blood. Allogenic transfusion in C.A.T.S patients decreased significantly (P < .0001). Mean intensive care unit stay was significantly reduced in C.A.T.S patients (P = .042). Mean postoperative hospital stay was 18 days for C.A.T.S group and 25 days in control patients (P = .014). The respective 30-day mortality was 12% versus 19% (P = .199). The C.A.T.S markedly reduced the amount of blood transfused, was associated with reduced intensive care unit and postoperative hospital stay, and was cost-effective.
No takes yet. Share an insight, caveat, or question.
Tawfick et al. (2008) conducted a cohort in Abdominal aortic aneurysm (n=187). Continuous AutoTransfusion System (C.A.T.S) vs. Control (no C.A.T.S) was evaluated on 30-day mortality (p=.199). The Continuous AutoTransfusion System (C.A.T.S) reduced mean postoperative hospital stay (18 vs 25 days, P=0.014) and allogenic transfusions, with 30-day mortality of 12% vs 19% (P=0.199).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: