Key result
Higher Tp-e interval was an independent predictor of mortality in patients undergoing surgical aortic valve replacement for severe aortic stenosis (OR 1.315; 95% CI 1.203-1.437; p<0.001).
Why the study?
The prognostic value of novel repolarization markers, including Tp-e interval, Tp-e/QT, and Tp-e/QTc ratios, on mortality had not been evaluated in patients undergoing surgical AVR for severe AS.
Cohort (n=375)
Answers are grounded in this paper and cite their sources.
Tp-e markers may aid post-AVR mortality risk stratification; leaves open validation in prospective cohorts before clinical use.
INTRODUCTION: Aortic stenosis (AS) is the most common degenerative valvular heart disease that can affect left ventricular functions. Tp-e interval and Tp-e/QT ratio is a novel repolarization marker which is associated with adverse cardiovascular events in several cardiovascular diseases. In our study, our aim is to investigate the prognostic effect of Tp-e interval, Tp-e/QT and Tp-e/QTc ratios on mortality in patients who underwent successful surgical aortic valve replacement (AVR). METHODS: A total of three hundred seventy-five patients undergoing successful surgical AVR were included in this study. Then, patients were divided into two groups according to mortality as group 1 without mortality (342 patients) and group 2 with mortality (33 patients). Tp-e interval, Tp-e/QT, and Tp-e/QTc ratios were calculated for both groups. RESULTS: Tp-e interval (71 (63.7-77); 86 (84-88), p < .001), Tp-e/QT ratio (0.19 (0.17-0.20); 0.23 (0.22-0.23), p < .001) and Tp-e/QTc ratio (0.17 ± 0.02; 0.21 ± 0.01, p < .001) were higher in group 2 compared to group 1. In multivariate logistic regression analyses Tp-e interval (odds ratio [OR]: 1.315, 95% confidence interval [CI]: 1.203-1.437, p < .001), Tp-e/QT ratio (OR: 7.334, 95% CI: 3.274-1.643, p < .001) and Tp-e/QTc ratio (OR: 2.567, 95% CI: 4.106-1.605, p < .001) were found to be independent predictors of mortality. Additionally, a Kaplan-Meier survival analysis also revealed that long term survival was found to be significantly decreased in patients with higher Tp-e/QT ratio (Log-Rank p < .001) and Tp-e/QTc ratio (Log-Rank p < .001). CONCLUSION: Tp-e interval, Tp-e dispersion, Tp-e/QT, and Tp-e/QTc ratios are associated with worse prognosis after surgical AVR in patients with severe AS. All of them are also independent predictors of mortality.
No takes yet. Share an insight, caveat, or question.
Avcı et al. (2021) conducted a cohort in Severe aortic stenosis (n=375). Tp-e interval, Tp-e/QT, and Tp-e/QTc ratios vs. Lower values was evaluated on Mortality (OR 1.315, 95% CI 1.203-1.437, p=<0.001). Higher Tp-e interval was an independent predictor of mortality in patients undergoing surgical aortic valve replacement for severe aortic stenosis (OR 1.315; 95% CI 1.203-1.437; p<0.001).
Synapse has enriched 10 related papers. Consider them for comparative context: