Key result
Switching to a vitamin E-bonded polysulfone dialyzer significantly improved intradialytic systolic, diastolic, and pulse pressures compared to baseline conventional dialyzers over 10 months.
Why the study?
Does a vitamin E-bonded polysulfone dialyzer improve intradialytic blood pressure in hemodialysis patients with intradialytic hypotension?
Does a vitamin E-bonded polysulfone dialyzer improve intradialytic blood pressure in hemodialysis patients with intradialytic hypotension?
A vitamin E-bonded polysulfone dialyzer may help prevent intradialytic hypotension in hemodialysis patients, though larger controlled trials are needed.
Answers are grounded in this paper and cite their sources.
May support vitamin E-bonded dialyzers for intradialytic hypotension; hypothesis-generating pending randomized trials.
BACKGROUND: Intradialytic hypotension (IDH) is a common clinical trait in hemodialysis (HD) which is caused by poor biocompatibility of the dialyzer membrane. Aiming to improve IDH, vitamin E-bonded polysulfone dialyzer (VPS-H) was evaluated in a pilot study. METHODS: Eight IDH patients on standard HD were switched from their conventional high-flux dialyzers to VPS-H, and intradialytic blood pressure (BP) was monitored regularly for 10 months. RESULTS: The results showed that hypotension of systolic BP (SBP), diastolic BP (DBP) and pulse pressure (PP) during the session were improved after changing the dialyzer. Notably, almost all the values recorded from 120 minutes into the session until the end of the treatment in the period between the second and tenth month after treatment were significantly different from the corresponding baseline values. Moreover, after 8 to 10 months, the SBP prior to a dialysis session was significantly reduced compared with baseline values. On the other hand, the pulse rate showed no difference throughout the study period. CONCLUSIONS: This study provides early evidence of the beneficial role that vitamin E-bonded dialyzers may have in preventing IDH. Larger controlled trials are needed to confirm this original finding.
No takes yet. Share an insight, caveat, or question.
Matsumura et al. (2010) studied Intradialytic hypotension (n=8). Vitamin E-bonded polysulfone dialyzer (VPS-H) vs. Conventional high-flux dialyzers (baseline) was evaluated on Intradialytic blood pressure (systolic, diastolic, and pulse pressure). Switching to a vitamin E-bonded polysulfone dialyzer significantly improved intradialytic systolic, diastolic, and pulse pressures compared to baseline conventional dialyzers over 10 months.
Synapse has enriched 10 related papers. Consider them for comparative context: