Existing and newly adapted techniques for suppressing harmonic responses in microstrip filters were combined. Stagger tuning using additional stubs to shift the resonances has been adapted to quarter-wave resonators and extended to the seventh-order spurious response. Suitable resonator overlap provided transmission zeroes to cancel spurious peaks. Coupling capacitor pads acting as shorting stubs have been developed. Spurious responses were suppressed to better than -33 dB, up to 6.3 GHz, in a measured filter with 1-GHz center frequency and 42% bandwidth. Suitably placed resistors have depressed the spurious level further to -50 dB up to 5.6 GHz, with only 0.07-dB extra passband loss.
No takes yet. Share an insight, caveat, or question.
F. Huang (2015) studied this question.
Synapse has enriched 3 closely related papers on similar clinical questions. Consider them for comparative context: