Answers are grounded in this paper and cite their sources.
The maximal neutral fraction from the passage of a D beam through a gas, as proposed for a gas neutraliser of reference ITER NBI concept, is 60%. The replacement of the gas neutraliser by a plasma one must increase the maximum neutral yield to 80%. This is an attractive improvement of the ITER NBI system. As the plasma neutraliser must be able to replace the gas neutraliser in the ITER NBI of the reference concept, its length is defined and equal to 3 meters. So, the necessary plasma density ne ∼ 7 × 1012 cm−3. We assume that PN should spend less than 2 MW of electrical power per one NBI module. The multicusp 3D magnetic wali configuration seems to be the best choice for PN plasma confinement system. This system can provide the necessary plasma confinement and an acceptable deviation effect on the beam ions. The plasma will be produced in steady – state mode of operation by the electrodeless microwave discharge at gas pressure less than 10−4 torr at mainly collisionless character of microwave energy absorption.
No takes yet. Share an insight, caveat, or question.
Kulygin et al. (1998) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: