Key result
Atrial Flow Regulator implantation was successfully performed in 100% of pediatric patients (10/10) with 0% procedural complications, though 30% died during follow-up from non-procedural causes.
Why the study?
Experience with the Atrial Flow Regulator to create interatrial communication in pediatric patients was limited to a few case reports.
Is the Atrial Flow Regulator safe and feasible in pediatric patients with congenital and acquired heart disease?
Observational (n=10)
No
Is the Atrial Flow Regulator safe and feasible in pediatric patients with congenital and acquired heart disease?
The Atrial Flow Regulator appears safe and feasible in a small cohort of pediatric patients with critical heart conditions, potentially improving hemodynamics and symptoms.
Supports feasibility in small pediatric series; leaves open need for prospective trials before clinical adoption.
Background The Atrial Flow Regulator (AFR; Occlutech) can be used to create interatrial communication with a predetermined diameter in various pathophysiological settings. In the pediatric population, the experience is limited to a few case reports. We aim to report the initial single-center experience of AFR implantation in children with congenital and acquired heart disease. Methods From December 2021 to June 2023, we enrolled 10 patients (aged 6 months-16 years). Indications to treatment were: left ventricular systolic dysfunction (n = 6), restrictive cardiomyopathy with pulmonary hypertension (n = 2), postoperative right ventricle dysfunction after surgical repair of a native Tetralogy of Fallot in a 12-year-old child (n = 1), and failure Fontan (n = 1). AFR implantation was successfully performed in all patients. Transseptal puncture was needed in 8 cases; in the other 2 cases, preexisting patent foramen ovale and fenestrated atrial septal defect were used. Balloon predilation was performed in 9 cases. An 8 mm device was implanted in all cases. The mean time of the procedure was 50 minutes, the median fluoroscopy time was 17 minutes, and median radiation exposure dose was 2.3 Gy × cm 2 . Results No complications were reported during the procedure. Three patients died during the follow-up: 1 due to sepsis (16 days after the procedure), 1 due to disease progression (8 months after), and 1 due to failure of ECMO decannulation 7 days after the atrial venting. In the remaining patients, a reduction of LA dilation, postcapillary pulmonary hypertension, and heart failure symptoms were observed. Conclusions AFR is safe and feasible in children and critical settings, allowing right/left cavities unloading and improvement of hemodynamics and symptoms.
No takes yet. Share an insight, caveat, or question.
Castaldi et al. (2023) conducted an observational in Congenital and acquired heart disease (n=10). Atrial Flow Regulator (AFR) implantation was evaluated on Procedural success. Atrial Flow Regulator implantation was successfully performed in 100% of pediatric patients (10/10) with 0% procedural complications, though 30% died during follow-up from non-procedural causes.