This is the authors' abstract. We don't add key points for this paper.
Backgroud: Intramedullary fixation has only uncommonly been used in the fibula although it may confer some advantages. Our goal was to investigate a single surgeon's learning curve with initial usage of an intramedullary device for fibular fixation based on surgical time and quality of reduction. Methods: Prior to initiation of this study, an experienced ankle fracture surgeon performed fibular nail fixation in a sawbones and a cadaver setting. Between February and August 2018, all patients who suffered from a distal fibula fracture underwent fibula fixation (n = 20) using the Fibulock (Arthrex). Patients were retrospectively investigated and compared with a control of fibular plate fixation. The tourniquet time, time of anesthesia, and surgery time were recorded as well as the quality of reduction. Two patients had slight malreductions (first and third cases): one was corrected with a lag screw outside the nail, the other was an elderly patient with significant blistering in whom an entirely percutaneous reduction was performed. Conclusions: Intramedullary fixation for fibular fractures does not appear to have a significant learning curve for an experienced ankle fracture surgeon.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Bäcker et al. (2020) studied this question.