Key result
SMN1 dosage analysis using quantitative real-time PCR in 150 individuals identified 50 (33.3%) with one copy, 87 (58%) with two copies, and 13 (8.7%) with zero copies.
Why the study?
Does quantitative Real-time PCR accurately determine SMN1 copy number in individuals undergoing SMA carrier testing?
Observational (n=150)
Does quantitative Real-time PCR accurately determine SMN1 copy number in individuals undergoing SMA carrier testing?
Quantitative real-time PCR accurately determines SMN1 copy number, aiding in the identification of SMA carriers and reducing unwarranted prenatal diagnoses.
qRT-PCR quantified SMN1 copies in tested individuals; leaves open its accuracy for SMA carrier screening pending validation.
BACKGROUND: Autosomal recessive spinal muscular atrophy is a disease resulting from homozygous absence of SMN1 gene in approximately 94% of SMA patients. To identify patients who retained a single SMN1 copy, SMN1 dosage analysis was performed by quantitative Real-time PCR using SYBR green dye. SMN1 dosage analysis results were utilized to identify carriers before offering prenatal diagnosis. METHOD: Carrier testing was performed for 150 individuals. Copy number of the SMN1 gene was determined by the comparative threshold cycle (Ct) method and human serum albumin gene was used as a reference. RESULT: Analysis of 150 DNA samples with quantitative PCR determined the number of SMN1 gene copies. Of these, 50 (33.33%) cases had one SMN1 gene copy, 87 (58%) had two copies and 13 (8.66%) did not have any copies of SMN1. The homozygous SMN1 deletion ratio was 0.00 and deletion of one copy of SMN1 gene ratio ranged from 0.3 to 0.58. CONCLUSION: This report demonstrates modification of risk estimation for the diagnosis and detection of SMA carriers by accurate determination of SMN1 copy number. SMN1 copy number analysis is an important parameter for identification of couples at risk of having children affected with SMA. It also reduces unwarranted prenatal diagnosis for SMA. Furthermore, the dosage analysis might be useful for the counseling of clinically suspected SMA patients with negative diagnostic SMA tests.
No takes yet. Share an insight, caveat, or question.
Abbaszadegan et al. (2011) conducted an observational in Spinal muscular atrophy (SMA) carrier status (n=150). SMN1 dosage analysis using quantitative real-time PCR was evaluated on SMN1 gene copy number. SMN1 dosage analysis using quantitative real-time PCR in 150 individuals identified 50 (33.3%) with one copy, 87 (58%) with two copies, and 13 (8.7%) with zero copies.