Key result
Neonatal circulatory transition causes significant left ventricular distortion at end-systole due to septal flattening that resolves by day 5, making standard M-mode echocardiography unreliable.
Why the study?
The transition from fetal to neonatal circulation produces marked alterations in relative right and left ventricular systolic and diastolic pressures that would be expected to influence global and regional left ventricular performance.
How do global and regional left ventricular mechanics change in normal newborns during the first days of life?
Observational
How do global and regional left ventricular mechanics change in normal newborns during the first days of life?
Standard M-mode echocardiographic assessment of left ventricular function is unreliable in newborns before day 4 due to transient septal flattening and altered regional wall motion.
Answers are grounded in this paper and cite their sources.
M-mode LV assessment may be unreliable in newborns before day 5; leaves open validation of alternative methods before clinical adoption.
The transition from fetal to neonatal circulatory status is accompanied by marked alteration in relative right and left ventricular systolic and diastolic pressure. These alterations would be expected to influence both global and regional performance of the left ventricle. To address this issue, sequential two-dimensional echocardiographic studies were performed in normal newborns during the first days of life. Global and regional left ventricular wall motion were quantified by computer digitization with the use of an automated edge detection algorithm and a floating-center-of-mass model. Comparison was made with a control group of normal infants and young children and the sequential change over the first 5 days of life was assessed. Newborns were found to have a circular left ventricular configuration at end-diastole beginning on day 1. At end-systole, however, there was significant left ventricular distortion due to septal flattening, which persisted until day 3 and resolved entirely by day 5 of life. Regional wall motion analysis demonstrated a corresponding augmentation of septal and contralateral left ventricular free wall systolic movement during the first days of life, with a normal pattern attained by day 4. Due to the nonhomogeneity of the left ventricular wall motion in the first few days of life, standard single-dimension shortening fraction provided an unreliable measure of global left ventricular performance before day 4. Thus, systolic right ventricular hypertension at a level sufficient to distort the left ventricular configuration is present until day 4 or 5 of life, resulting in altered left ventricular regional wall motion. As a result, usual M mode echocardiographic assessment of left ventricular function is unreliable in this age group.(ABSTRACT TRUNCATED AT 250 WORDS)
No takes yet. Share an insight, caveat, or question.
Rein et al. (1987) conducted an observational in Normal newborns. Neonatal circulatory transition vs. Normal infants and young children was evaluated on Global and regional left ventricular wall motion. Neonatal circulatory transition causes significant left ventricular distortion at end-systole due to septal flattening that resolves by day 5, making standard M-mode echocardiography unreliable.