Key result
Atherosclerotic ApoE(-/-) mice had a significantly higher mean aortic pulse wave velocity (3.0 ± 0.6 m/s) compared to healthy C57Bl/6J mice (2.4 ± 0.4 m/s, p=0.014) as measured by high-field CMR.
Absolute Event Rate: 3% vs 2.4%
p-value: p=0.014
High-field CMR at 17.6 Tesla using a transit time method can non-invasively measure and distinguish aortic pulse wave velocity in healthy and atherosclerotic mouse models.
Demonstrates feasibility of high-field CMR for aortic PWV assessment in atherosclerotic mice; hypothesis-generating for preclinical vascular research.
BACKGROUND: Transgenic mouse models are increasingly used to study the pathophysiology of human cardiovascular diseases. The aortic pulse wave velocity (PWV) is an indirect measure for vascular stiffness and a marker for cardiovascular risk. RESULTS: This study presents a cardiovascular magnetic resonance (CMR) transit time (TT) method that allows the determination of the PWV in the descending murine aorta by analyzing blood flow waveforms. Systolic flow pulses were recorded with a temporal resolution of 1 ms applying phase velocity encoding. In a first step, the CMR method was validated by pressure waveform measurements on a pulsatile elastic vessel phantom. In a second step, the CMR method was applied to measure PWVs in a group of five eight-month-old apolipoprotein E deficient (ApoE(-/-)) mice and an age matched group of four C57Bl/6J mice. The ApoE(-/-) group had a higher mean PWV (PWV = 3.0 ± 0.6 m/s) than the C57Bl/6J group (PWV = 2.4 ± 0.4 m/s). The difference was statistically significant (p = 0.014). CONCLUSIONS: The findings of this study demonstrate that high field CMR is applicable to non-invasively determine and distinguish PWVs in the arterial system of healthy and diseased groups of mice.
No takes yet. Share an insight, caveat, or question.
Parczyk et al. (2010) studied Atherosclerosis (n=9). ApoE(-/-) genotype with western diet vs. C57Bl/6J wild-type mice was evaluated on Aortic pulse wave velocity (PWV) (p=0.014). Atherosclerotic ApoE(-/-) mice had a significantly higher mean aortic pulse wave velocity (3.0 ± 0.6 m/s) compared to healthy C57Bl/6J mice (2.4 ± 0.4 m/s, p=0.014) as measured by high-field CMR.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: