OBJECTIVE: To report ventilation strategies, survival and complications in 39 outborn infants treated with high frequency oscillatory ventilation (HFOV). METHODOLOGY: Data were collected prospectively between 1 May 1992 and 31 December 1993 on all infants treated with HFOV who had severe respiratory failure despite optimal conventional ventilation. RESULTS: Twenty-eight out of 39 (72%) survived. Of the 15 infants with birthweights < 1500 g, eight survived. Best survival rates were for infants with pulmonary interstitial emphysema with air leak (4/5) and for infants of birthweight > 1500 g with hyaline membrane disease (8/8), and meconium aspiration syndrome (7/7). Three infants deteriorated while on HFOV and required extracorporeal membrane oxygenation. Complications were: (i) development of pulmonary interstitial emphysema (1); (ii) recurrence of pneumothorax (3); (iii) hypotension (2); and (iv) bronchopulmonary dysplasia (9). One of the eight infants weighing < 1500 g who received HFOV in the first week of life developed periventricular haemorrhage. CONCLUSION: The initial results of HFOV for severe failure were encouraging although a learning curve was encountered with its introduction.
No takes yet. Share an insight, caveat, or question.
McDOUGALL et al. (1995) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: