Key result
Surgical removal of a broken right coronary artery catheter via an aortic incision during emergency coronary artery bypass graft surgery was successfully accomplished.
Case Report (n=1)
A broken catheter in the aorta during coronary angiography is a rare but catastrophic event that can be safely removed surgically during concomitant emergency bypass surgery.
Answers are grounded in this paper and cite their sources.
Supports surgical retrieval option in this rare event during emergency CABG; leaves open standardized approaches pending additional cases.
The complications linked directly to coronary artery catheter itself are very rare. We presented a case in which the broken right coronary artery catheter was successfully removed from the ascending aorta. The removal of catheter was accomplished via an aortic incision, which was created for saphenous vein graft in the site of anastomosis during an emergency coronary artery bypass graft surgery. We believe that a broken catheter in the aorta is a catastrophic event, which could be removed safely in the operating room even with concomitant bypass surgery.
No takes yet. Share an insight, caveat, or question.
Küçükarslan et al. (2007) conducted a case report in Broken coronary artery catheter during coronary angiography (n=1). Surgical removal via aortic incision during emergency CABG was evaluated on Successful removal of broken catheter. Surgical removal of a broken right coronary artery catheter via an aortic incision during emergency coronary artery bypass graft surgery was successfully accomplished.
Synapse has enriched 10 related papers. Consider them for comparative context: