Key result
Transesophageal echocardiography guidance for Avalon cannula placement resulted in significantly fewer flow problems compared to fluoroscopy (0% vs 80%, p=0.024).
Why the study?
Correct placement of the Avalon bicaval dual-lumen cannula for VV ECMO requires image guidance, but institutional ECMO performance, cannulation complications, and malposition had not been compared between fluoroscopy and TEE.
Does transesophageal echocardiography (TEE) guidance reduce cannula malposition and improve ease of cannulation compared to fluoroscopy in patients undergoing Avalon cannula placement for VV ECMO?
Cohort (n=10)
No
Does transesophageal echocardiography (TEE) guidance reduce cannula malposition and improve ease of cannulation compared to fluoroscopy in patients undergoing Avalon cannula placement for VV ECMO?
TEE guidance for Avalon cannula placement in VV ECMO significantly reduces the incidence of low flows compared to fluoroscopy.
TEE may reduce low flows in Avalon placement; leaves open need for RCTs before practice change.
The Avalon elite bicaval dual-lumen cannula for single site VenoVenous Extracorporeal Membrane Oxygenation (VV ECMO) offers several advantages. Correct placement of the Avalon cannula is safe using image guidance and needs either fluoroscopy or Transesophageal echocardiography (TEE). We assessed our institutional ECMO performance, cannulation related complications, instances of cannula malposition among patients cannulated using the two imaging modalities. We reviewed all patients who had Avalon cannula placement for VV ECMO at our institute. Ten patients were included in the study. Patients were cannulated using either fluoroscopy (Group A, n = 5) or TEE (Group B, n = 5). Data included patient demographics, diagnosis, evidence of cannula malposition, ECMO performance, cannulation related complications. The primary outcomes ease of cannulation; cannula malposition and the need for repositioning were compared between the two groups. Visualisation of guidewire, Avalon cannula and the average number of attempts to cannulate were similar (P > 0.05) between the two groups. Four patients cannulated using fluoroscopy had low flows whereas none of the patients cannulated using TEE had flow problems which was statistically significant (P = 0.024). Four cannulas (80%) placed under fluoroscopy required repositioning whereas one cannula (20%) placed under TEE needed repositioning. This difference was not statistically significant though (P = 0.099). TEE is the ideal imaging modality to guide Avalon elite cannula placement for VV ECMO.
No takes yet. Share an insight, caveat, or question.
Hemamalini et al. (2020) conducted a cohort in Acute respiratory failure requiring VV ECMO (n=10). Transesophageal echocardiography (TEE) vs. Fluoroscopy was evaluated on Flow problems on initiation of VV ECMO (p=0.024). Transesophageal echocardiography guidance for Avalon cannula placement resulted in significantly fewer flow problems compared to fluoroscopy (0% vs 80%, p=0.024).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: