Key result
Imaging guidance using TEE and X-ray successfully identified and corrected retrograde cranial malposition of central line guidewires in a patient with complex anatomy undergoing VAV-ECMO.
Why the study?
Central venous catheter malposition occurs in up to 6.7% of cases, and pre-induction VAV-ECMO cannulation combined with anatomical distortion presents unique challenges for proper placement.
Case Report (n=1)
Imaging guidance with TEE and X-ray is valuable for achieving proper CVC placement in VAV-ECMO patients with complex anatomical challenges.
Extracorporeal membrane oxygenation (ECMO) has become increasingly utilized both electively and emergently to provide cardiac and/or respiratory support. Central venous catheter (CVC) access is essential for hemodynamic monitoring, administering critical medications, and enabling rapid interventions, such as massive transfusions during surgery. Proper CVC position is essential for its appropriate function and to avoid complications. However, malposition occurs in up to 6.7 % of cases, increasing the risks of catheter dysfunction and mortality-morbility. In our case, a patient with a massive liver metastasis extending into the right chest, causing diaphragm elevation and leftward heart shift, was scheduled for complex surgery with pre-induction Veno-Arterial-Venous ECMO (VAV-ECMO) cannulation in the superior vena cava via right internal jugular (IJ) vein. This presented unique challenges for CVC placement via left IJ vein. When guidewires were not visualized by intraoperative transesophageal echocardiography (TEE), X-ray was used to identify cranial retrograde malposition of guidewires. The guidewires of CVC were subsequently repositioned under TEE and X-ray guidance. This case report highlights the value of imaging guidance in achieving proper CVC placement in VAV-ECMO patient with complex anatomical cases.
No takes yet. Share an insight, caveat, or question.
Shafquat et al. (2024) conducted a case report in Veno-Arterial-Venous ECMO patient with massive liver metastasis and altered anatomy (n=1). Imaging guidance (TEE and X-ray) for CVC placement was evaluated on Identification and repositioning of malpositioned guidewires. Imaging guidance using TEE and X-ray successfully identified and corrected retrograde cranial malposition of central line guidewires in a patient with complex anatomy undergoing VAV-ECMO.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: