Key result
U-suture femoral cannulation yields ~1% mid-term vascular complications in robotic cardiac surgery.
Cohort (n=216)
No
Femoral artery cannulation using the U-suture technique without arteriotomy or clamping is associated with low rates of mid-term vascular stenosis, thrombosis, and local wound complications in patients undergoing robotic cardiac surgery.
Answers are grounded in this paper and cite their sources.
Supports U-suture femoral cannulation safety in robotic surgery; leaves open randomized confirmation before wider adoption.
INTRODUCTION: Various surgical procedures for minimally invasive cardiac surgery have been described in recent decades as alternatives to median sternotomy. Cardiopulmonary bypass via femoral arterial and venous cannulation is the foundation of these procedures. In this study, we evaluated the mid-term outcomes of femoral cannulation performed with U-suture technique in patients undergoing robotic heart surgery. METHODS: A total of 216 patients underwent robotic-assisted cardiac surgery between January 2013 and April 2017. Cardiopulmonary bypass was performed via femoral artery, jugular, and femoral vein cannulation, and a Chitwood clamp was used for aortic occlusion. A total of 192 patients attended the outpatient follow-up, and femoral arterial and venous flow pattern was examined using Doppler ultrasound (DUS) in 145 patients. RESULTS: Hospital mortality occured in 4 of the 216 (1.85%) cases, but there was no late mortality in this patient group. Postoperatively, seroma (n=9, 4.69%) and cannulation site infection (n=3, 1.56%) were managed with outpatient treatment. DUS in 145 patients revealed triphasic flow pattern in the common femoral arteries in all patients except for 2 (1.38%). These patients were determined to have asymptomatic arterial stenosis. Chronic recanalized thrombus in the common femoral vein was also detected in 2 (1.38%) patients. CONCLUSION: Femoral artery cannulation with the U-suture technique can be successfully performed in robotic-assisted cardiac surgery, with good mid-term results.
No takes yet. Share an insight, caveat, or question.
Şen et al. (2018) conducted a cohort in Valvular heart disease or atrial septal defect undergoing robotic-assisted cardiac surgery (n=216). Femoral arterial and venous cannulation using the U-suture technique was evaluated on Common femoral artery stenosis and common femoral vein thrombosis on mid-term Doppler ultrasound (n=145). Femoral cannulation with the U-suture technique in robotic cardiac surgery resulted in 1.38% asymptomatic common femoral artery stenosis and 1.38% chronic femoral vein thrombus on mid-term ultrasound.
Synapse has enriched 10 related papers. Consider them for comparative context: