Key result
Fast start high-intensity interval exercise resulted in a similar percentage of training time spent above 90% of VO2max compared to steady power exercise.
Why the study?
The study compared the acute oxygen consumption response of fast start versus steady power high-intensity interval exercise matched for W' depletion.
Does fast start high-intensity interval exercise compared to steady power exercise alter the acute oxygen consumption response in cyclists?
Does fast start high-intensity interval exercise compared to steady power exercise alter the acute oxygen consumption response in cyclists?
When high-intensity interval exercise formats are matched based on W' expenditure, fast start and steady power formats elicit similar time spent above 90% of VO2max.
Answers are grounded in this paper and cite their sources.
Equivalent VO2 responses with W’-matched HIIE protocols; leaves open effects on performance and adaptation in endurance athletes.
The current investigation compared the acute oxygen consumption (VO2) response of two high-intensity interval exercises (HIIE), fast start (FSHIIE), and steady power (SPHIIE), which matched w prime (W’) depletion. Eight cyclists completed an incremental max test and a three-minute all-out test (3MT) to determine maximal oxygen consumption (VO2max), critical power (CP), and W’. HIIE sessions consisted of 3 X 4 min intervals interspersed by 3 min of active recovery, with W’ depleted by 60% (W’target) within each working interval. SPHIIE depleted the W’target consistently throughout the 3 min intervals, while FSHIIE depleted the W’target by 50% within the first minute, with the remaining 50% depleted evenly across the remainder of the interval. The paired samples t-test revealed no differences in the percentage of training time spent above 90% of VO2max (PT ≥ 90% VO2max) between SPHIIE and FSHIIE with an average of 25.20% and 26.07%, respectively. Pairwise comparisons indicated a difference between minute 1 peak VO2, minute 2, and minute 3, while no differences were present between minutes 2 and 3. The results suggest that when HIIE formats are matched based on W’ expenditure, there are no differences in PT ≥ 90% VO2max or peak VO2 during each interval.
No takes yet. Share an insight, caveat, or question.
Miller et al. (2023) studied this question. Fast start high-intensity interval exercise (FSHIIE) vs. Steady power high-intensity interval exercise (SPHIIE) was evaluated on Percentage of training time spent above 90% of VO2max (PT ≥ 90% VO2max). Fast start high-intensity interval exercise resulted in a similar percentage of training time spent above 90% of VO2max compared to steady power exercise.
Synapse has enriched 10 related papers. Consider them for comparative context: