Key result
A mild dyssynchronous contraction pattern detected by SPECT myocardial perfusion imaging predicted a higher rate of cardiac resynchronization therapy super-response compared to a heterogeneous pattern.
Why the study?
The study aimed to identify the predictive value of a new contraction pattern for CRT response using SPECT MPI with phase analysis.
Does a mild dyssynchronous contraction pattern detected by SPECT MPI predict CRT super-response in non-ischemic DCM patients with LBBB?
Observational (n=74)
No
Does a mild dyssynchronous contraction pattern detected by SPECT MPI predict CRT super-response in non-ischemic DCM patients with LBBB?
A mild dyssynchronous contraction pattern on SPECT MPI predicts CRT super-response and better long-term prognosis in patients with non-ischemic DCM and LBBB.
Answers are grounded in this paper and cite their sources.
Hypothesis-generating for SPECT PA contraction pattern in CRT; prospective validation required before clinical adoption.
Background: Using single photon emission computed tomography myocardial perfusion imaging (SPECT MPI) with phase analysis (PA), we aimed to identify the predictive value of a new contraction pattern in cardiac resynchronization therapy (CRT) response. Methods: Left ventricular mechanical dyssynchrony (LVMD) was evaluated using SPECT MPI with PA in non-ischemic dilated cardiomyopathy (DCM) patients with left bundle branch block (LBBB) indicated for CRT. CRT super-response was defined as LV ejection fraction (EF) ≥50% or an absolute increase of LVEF >15%. The LV contraction was categorized as the mild dyssynchronous pattern when the phase standard deviation (PSD) ≤ 40.3° and phase histogram bandwidth (PBW) ≤ 111.9°, otherwise it was defined as severe dyssynchronous pattern which was further characterized as U-shaped, heterogeneous or homogenous pattern. Compared to patients with the heterogeneous pattern, the odds ratios (ORs) with 95% confidence intervals (CIs) for CRT super-response were 10.182(2.43-42.663), 12.8(2.545-64.372), and 2.667(0.327-21.773) for patients with mild dyssynchronous, U-shaped, and homogenous pattern, respectively. After multivariable adjustment, mild dyssynchronous group remained associated with increased CRT super-response (adjusted OR 5.709, 95% CI 1.152-28.293). Kaplan-Meier curves showed that mild dyssynchronous group demonstrated a better long-term prognosis. Conclusions: The mild dyssynchronous pattern in patients with DCM is associated with an increased CRT super-response and better long-term prognosis.
No takes yet. Share an insight, caveat, or question.
Qian et al. (2022) conducted an observational in Non-ischemic dilated cardiomyopathy with left bundle branch block (n=74). Mild dyssynchronous contraction pattern vs. Heterogeneous contraction pattern was evaluated on CRT super-response (LVEF ≥ 50% or absolute increase >15% at 6 months) (adjusted OR 5.709, 95% CI 1.152-28.293, p=0.033). A mild dyssynchronous contraction pattern detected by SPECT myocardial perfusion imaging predicted a higher rate of cardiac resynchronization therapy super-response compared to a heterogeneous pattern.
Synapse has enriched 10 related papers. Consider them for comparative context: