Answers are grounded in this paper and cite their sources.
This paper presents a high-precision fiber optic temperature monitoring system based on FBG-GaAs dual-mode collaborative measurement. The system innovatively implements a dual-mode collaborative mechanism utilizing a GaAs crystal FP cavity integrated with FBG. The FBG provides coarse measurement with a sensitivity of 0.011 nm/∘C, enabling rapid temperature positioning across a wide range from -20 ∘C to 150 ∘C. Simultaneously, the GaAs component delivers fine measurement with a sensitivity of 0.12 nm/∘C for high-resolution compensation. This approach resolves the spectral overlap issue that traditional FP interferometers face in wide temperature ranges. Experimental results demonstrate that the system achieves a maximum sampling rate of 6000 Hz with a temperature demodulation error of ±0.41 ∘C, showing superior advantages in wide temperature adaptability compared to similar sensors.
No takes yet. Share an insight, caveat, or question.
Zhang et al. (2025) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: