Key result
The Stationary Wavelet Movement Artifact Reduction (SWMAR) algorithm reduced movement artifacts in equine ECG recordings by over 40%, significantly outperforming the standard adaptive filter technique (p<0.05).
Why the study?
Does the SWMAR algorithm reduce movement artifacts in ECG signals from horses compared to NLMSAF?
Does the SWMAR algorithm reduce movement artifacts in ECG signals from horses compared to NLMSAF?
p-value: p=<0.05
The SWMAR algorithm effectively reduces movement artifacts in wearable ECG recordings from horses, outperforming standard adaptive filtering techniques.
May improve equine ECG monitoring in veterinary research; leaves open translation to human clinical practice.
This study reports on a novel method to detect and reduce the contribution of movement artifact (MA) in electrocardiogram (ECG) recordings gathered from horses in free movement conditions. We propose a model that integrates cardiovascular and movement information to estimate the MA contribution. Specifically, ECG and physical activity are continuously acquired from seven horses through a wearable system. Such a system employs completely integrated textile electrodes to monitor ECG and is also equipped with a triaxial accelerometer for movement monitoring. In the literature, the most used technique to remove movement artifacts, when noise bandwidth overlaps the primary source bandwidth, is the adaptive filter. In this study we propose a new algorithm, hereinafter called Stationary Wavelet Movement Artifact Reduction (SWMAR), where the Stationary Wavelet Transform (SWT) decomposition algorithm is employed to identify and remove movement artifacts from ECG signals in horses. A comparative analysis with the Normalized Least Mean Square Adaptive Filter technique (NLMSAF) is performed as well. Results achieved on seven hours of recordings showed a reduction greater than 40% of MA percentage (between before- and after- the application of the proposed algorithm). Moreover, the comparative analysis with the NLMSAF, applied to the same ECG recordings, showed a greater reduction of MA percentage in favour of SWMAR with a statistical significant difference (p-value < 0.0.5).
No takes yet. Share an insight, caveat, or question.
Lanatà et al. (2015) studied Movement artifacts in ECG (n=7). Stationary Wavelet Movement Artifact Reduction (SWMAR) algorithm vs. Normalized Least Mean Square Adaptive Filter (NLMSAF) technique was evaluated on Movement artifact (MA) percentage (p=<0.05). The Stationary Wavelet Movement Artifact Reduction (SWMAR) algorithm reduced movement artifacts in equine ECG recordings by over 40%, significantly outperforming the standard adaptive filter technique (p<0.05).
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: