The authors report the use of high-performance liquid chromatography (HPLC) and time-of-flight secondary ion mass spectrometry (TOF-SIMS) utilizing a gas cluster ion beam to accurately measure the dopant concentration and its depth profile in organic thin films used for organic light-emitting diodes. The total dopant concentrations estimated by HPLC for films of 4,4'-bis(carbazol-9-yl)biphenyl (CBP) doped with tris(2-phenylpyridinato)iridium(III) (Ir(ppy)3) are consistent with those measured by quartz crystal microbalances (QCMs) during the deposition. Concentrations measured for Ir(ppy)3:CBP films by HPLC and TOF-SIMS show a nearly linear relationship in the range of 1–8 wt. %. At concentrations higher than 8 wt. %, TOF-SIMS values significantly deviate because of the matrix effect. The depth profile of the dopant concentration measured by TOF-SIMS was in good agreement with that measured by QCMs during film deposition for concentrations below 8 wt. %. These methods are especially useful for comparing the dopant concentration of films deposited in different batches and equipment.
No takes yet. Share an insight, caveat, or question.
Fujimoto et al. (2014) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: