Answers are grounded in this paper and cite their sources.
High-frequency-link power conversion and distribution based on a resonant inverter has been recently proposed. The design of several topologies is reviewed and a simple approximate design procedure is developed for the phase-controlled parallel-loaded resonant inverter. This design procedure seeks to ensure the expected benefits of resonant conversion and is verified by data from a laboratory 2.5 kVA, 20-kHz converter. A simple phasor analysis is introduced as a useful approximation for design purposes. Experimental results show that under transient conditions such as load short-circuit, a reversal of the expected commutation sequence is possible. This should be accounted for in the design of the power circuit, or prevented by the design of the controller.>
No takes yet. Share an insight, caveat, or question.
R. King (1989) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: