Answers are grounded in this paper and cite their sources.
Case report demonstrates hybrid wiring and unilateral Goel–Harms fixation for pediatric craniovertebral anomaly, suggesting a safe approach when vertebral artery course precludes bilateral screws.
Key Message: Different fixation strategies exist in CVJ anomalies, each with strengths and weaknesses. Different techniques allow us to cover their weaknesses and bolster their collective advantages. The patient was taken up for posterior fixation for mobile bony CVJ anomaly with the anomalous course of the vertebral artery (VA) after obtaining written and informed consent from the parents. A detailed discussion was done with parents before the surgery regarding the probable outcomes and the prognosis of the case. The patient was intubated and positioned prone with proper cushioning of pressure points. The head was kept on a horseshoe headrest fixed rigidly to the table. We made sure that there was no compression of the eyes and abdomen. Peripheral pulses were also checked in the upper and lower limbs. Painting and draping were done. A midline linear incision 2 cm above the occiput to the C3 vertebral level was given [Figure 1]. Subperiosteal exposure of subocciput, C1 posterior arch, and C2 lamina was done. The Foramen magnum was deeply and widely decompressed using a high-speed drill. The foramen magnum rim was removed with upcuts. C1-2 sublaminar steel wire loops were passed through using the number 1 silk suture as a guide. The tricortical left posterior iliac crest graft was harvested. Right C1-2 Goel–Harms Lateral Mass-Pars screw rod fixation was done. The iliac crest graft was placed in C1-2 interlaminar space between the two ends of the wire loops, and manual posterior compression over the graft was done using the C1-2 screw rod construct. Final wire tensioning was done using clamps. Figure 2 shows the final construct after instrumentation. The wound was sutured in layers.Figure 1: Incision from 2 cm above inion to C3 spinous processFigure 2: Final construct after instrumentationVideo Link https://youtu.be/22oTMbIk8yc QR code Video timeline with audio transcript 00.0 – 0.10 This is an operative video demonstrating the Sonntag posterior wiring technique supplemented with a unilateral Goel–Harms C1–C2 fixation for mobile pediatric craniovertebral junction anomaly. 0.14 – 0.34 The patient is a nine-year-old male with a history of multiple episodes of falls at ground level who is currently ambulatory with distal muscle wasting, grip weakness, subtle pyramidal signs, and a positive Rhomberg test. 0.35 – 0.44 The lateral view X-ray of the CVJ reveals an increased Atlantodental Interval (ADI) of 8 mm with a complete reduction in the extension. 0.45 – 0.51 Sagittal sections of T2-weighted MRI reveal severe cord compression with signal changes. 0.52 – 1.02 Sagittal sections of the computed tomography and angiography (CTA) imaging show the absence of basilar invagination. 1.03 – 1.09 Coronal sections of the CTA reveal an anomalous course of the left VA. 1.10 – 1.25 Volume-rendered imaging better demonstrates the anomalous course of the left VA through the posterior arch of C1 rather than over it, signifying the presence of an anomalous first intersegmental artery on the left side. 1.26 – 1.28 The patient is positioned prone, and the head is neutral with adequate padding and support. 1.29 – 1.42 A linear midline suboccipital incision from 2 centimeters above inion to C3 spinous process is made to define the occiput, C1 posterior arch, and C2 lamina subperiosteally. 1.43 – 1.52 The superior surface of the C1 posterior arch is being defined using subperiosteal dissection. 1.53 – 2.01 C1 sublaminar space is next defined using subperiosteal dissection. 2.02 – 2.21 Posterior compression on the cord at the CVJ is relieved by Foramen magnum decompression using a high-speed drill and then Kerrison Rongeur. 2.22 – 2.34 The C2 spinous process is nibbled off both to create space for instrumentation and to harvest graft material. 2.35 – 2.58 Once adequate space has been created, the number 1 silk suture is passed in a superior to inferior direction beneath the posterior arch of C1 and lamina of C2 bilaterally. 2.59 – 3.51 Once bilateral guiding sutures have been passed in a sublaminar fashion, steel wire loops are passed in a similar manner. Care has to be taken to prevent undue thecal sac compression and shear while passing the wire. Problems can be encountered, especially in the narrow C2 sublaminar space and while extracting the wires at the inferior border of the C2 lamina. Instead of large jerky movements, multiple controlled micromovements can be used at this step to extract the wires safely. 3.52 – 4.06 Both wires are being lateralized in the spinal canal. 4.07 – 4.11 A tricortial posterior iliac crest graft has been harvested in a standard fashion, and the fit is being trialed at this stage. 4.12 – 4.29 The right C1-2 joint is being distracted. 4.30 – 4.46 The right C2 nerve root is being lifted and cut to expose the C1 lateral mass and C1–C2 joint space adequately. 4.47 – 4.57 The right C1 lateral mass comes into view. 4.58 – 5.21 A high-speed drill is used to make the pilot hole for the C1 lateral mass screw. 5.22 – 5.28 A ballpoint probe is used to palpate the walls, and the trajectory is confirmed using a lateral radiograph. 5.29 – 5.40 We proceeded with a hand drill to enlarge and extend the screw trajectory and which is being confirmed on lateral radiographs. 5.41 – 5.51 A 3.5 × 30 mm size screw is inserted, and its position confirmed on radiographs. 5.52 – 6.08 The pilot hole for the C2 pars screw is made using drill 3 mm cranial and lateral to inferomedial corner of the inferior articulating facet of C2. 6.09 – 6.19 Enlargement and extension of screw trajectory are made using a hand drill while inspecting the superior surface of C2 pars for proper cranial angulation. 6.20 – 6.37 Sequentially, after palpating bony walls using a ballpoint probe, a 3.5 × 14 mm size C2 pars screw is inserted, and its position is confirmed by a lateral radiograph. 6.38 – 6.47 Decortication of the inferior surface of the posterior arch of C1 and the superior surface of C2 lamina is done using a high-speed drill. 6.48 – 6.54 The iliac crest graft is placed in the C1-2 interlaminar space 6.55–7.03. Manual Posterior Compression over the iliac crest graft is achieved next. 7.04 – 7.24 Finally, the wires are tightened using a cable tightener. 7.25 – 7.43 Postoperative CT scan shows appropriate placement of the construct and adequate widening of the canal at the craniovertebral junction. 7.44 – 7.53 Postoperatively, the patient is independently ambulating without support. 7.54 – 7.59 Two-month follow-up radiograph demonstrating the construct. Outcome Postoperatively, the child was monitored in the Neurosurgery Intensive Care Unit. Measures are taken to prevent hypothermia. The child was extubated on postoperative day 1. Vitals were stable throughout without a fever spike. Postoperatively, the child had improvement in motor power and hand grip. The child was independently ambulating on postoperative day 3 with improvement in ataxia. The child was discharged on postoperative day three. The wound was healthy at the time of discharge and after suture removal. A 2-month follow-up radiograph demonstrates the construct anatomy. Pearls and Pitfalls Pearls CVJ wiring techniques have a place in the modern surgeon’s armamentarium in cases with anomalous VA course/small CVJ anatomy unsuitable for even the smallest screws. To enhance the rotational stability of the wiring construct, which has been its classic weakness, screw rod fixation can be used to complement it, as has been done in this case. Wiring helped us for compression of C1 and C2 on the other side, which is again essential for reduction of atlantoaxial dislocation and maintenance of the reduction without overt stress on the contralateral screw-rod construct. In addition, bone graft from iliac crest graft will help in the fusion of posterior elements in a corrected state. Although bilateral constructs have better biomechanical strength, several research articles[1-4] are available saying that unilateral C1–C2 fixation is a good alternative in the presence of neurovascular contraindications with similar strength and good bony fusion compared to bilateral while requiring additional use of external orthosis to achieve good fusion. We have provided external orthosis in terms of customized hard collars with good compliance from the patient. Hybrid techniques offer clinical results comparable to traditional symmetric fixations.[5] Pitfalls Although left-sided bones were mature enough to receive screws the same as on the right side, the need to mobilize the anomalous vertebral artery was the obstacle because there was excessive venous oozing on attempting to mobilize the vertebral artery, so it was abandoned to avoid blood loss in the child. The meta-analysis by Ghaith AK et al.[6] concluded that the rate of Vertebral Artery Injury (VAI) after C1–C2 posterior cervical fusion was found to be 2% for each operated patient and 1% for each screw placed, and anomalous arteries being one of the major predisposing factors for VAI. We could not show the incision or demonstrate the procedure for harvesting a bone graft from the posterior iliac crest in the video, so we demonstrated it pictorially in the manuscript. Discussion CVJ is an anatomically and embryologically complex location with intricate biomechanics and kinematics.[7] Bony CVJ anomalies are complex pathologies resulting from anomalous embryological development and segmentation. Multiple variations exist, and the complex pathoanatomy may necessitate different treatment strategies to be employed, including wiring, C1 lateral mass - C2 pars fixation, O-C Fixation, C1-2 transarticular fixation, use of translaminar screws, etc.[8] Entry points, trajectories, and average sizes of different C1 C2 screws have been mentioned in Table 1.Table 1: Entry points, trajectories, and average sizes of posterior C1 and C2 screwsOccipital fixation is necessary when the atlas is assimilated or has anomalous anatomy, such as a bifid posterior arch, thus weakening the atlas anchor point in the construct. C1-2 transarticular screw fixation necessitates a difficult trajectory, a mobile anomaly, and preexisting reduction; it is also very challenging if the VA course is anomalous or high riding. Multiple challenges exist in the instrumentation of the pediatric spine, some being the smaller anatomy, poorly corticated bone with fewer remodeling cycles and lower mechanical strength. Novel strategies have been developed recently for complex pathologies with atlas assimilation, allowing these entities to be addressed with a posterior-only approach without resorting to odontoidectomy.[9,10] Each surgical strategy has pros and cons; an individualized surgical plan for each patient must be tailored according to the pathology. In this case, as the left VA has an anomalous course, placing C1-2 screws is not impossible but can be risky, especially in a pediatric patient. Hence, Sonntag wiring was the safer option for achieving reduction and translational stability. Sonntag and Dickman modified Gallie’s technique (1991) in which an adequately sized iliac crest graft was placed in between the decorticated inferior surface of C1 and the decorticated superior surface of C2, and the construct was tightened using sublaminar wires.[8] In the original Gallie’s technique, the bone graft was simply leaned over the posterior arch of C1 and inferiorly notched over the C2 spinous process before being tightened with wires. Sonntag’s wiring technique had 97% fusion rates,[8] so it is an excellent technique to implement in the pediatric population, especially along with screw rod constructs, like in this case. Wiring might cause dural injury in the sublaminar space. It must be done carefully in small children due to the lower mechanical strength of the substrate, which might cause sequelae such as cheese wiring on the tightening of the wires. Wiring is also impossible if the osseous integrity of the posterior arch of the C1 or C2 lamina is compromised due to anomalous development such as a bifid posterior arch. Another drawback of wiring is the lack of rigid fixation and rotational stability, thus requiring prolonged immobilization; to counter this in the construct, a unilateral Goel–Harms C1-2 fixation was done, which will add much-needed rotational stability and rigidity.[11,12] This construct thus enabled us to mobilize the patient relatively early with a hard cervical collar. Wide and generous foramen magnum decompression is not always required. Still, it is sometimes essential if there is excessive crowding near the cord at the CVJ, especially in cases of complex chiari malformations. C2 nerve root, in our case, was sacrificed on the right side, but that should be avoided unless there is complex osseovascular anatomy hindering joint preparation; otherwise, there may be complications like occipital paresthesia, dysesthesia, or hypoesthesia and occipital ulcer formation, which may require skin grafting.[13] Persistent First Intersegmental Artery This is a common VA anomaly in which the vertical channel between C1 and C2 disappears during embryogenesis. The first intersegmental artery (FIA) persists to act as the V3 segment of the VA, which passes posterior to the C1–C2 joint and passes through the C1 posterior arch. This causes difficulty during C1–C2 joint manipulations and instrumentation. In our case, a similar situation was seen on the left side. FIA or any other VA anomaly is not a deterrent to joint drilling, spacer insertion, and manipulation.[14] The VA can be patiently dissected, mobilized, and safeguarded during manipulating C1–C2 joints.[15] The screw can be inserted above the anomalous VA by retracting it caudally if it is persistent FIA or vice versa if it is an inverted VA. The artery must be mobilized and retracted along its good length to avoid undue traction. The space of the joint medial/lateral to the artery can be utilized to drill it flat in all planes and insert bone chips/spacers in case of FIA. A more medial C2 transverse foramen provides more space lateral to the FIA for drilling to prepare joint space and vice versa.[16] In cases of VA fenestration, there is a risk of avulsion from the main artery of the thinner segment of the artery crossing the C1–C2 joint while manipulating and dissecting the joint space so it can be sacrificed. If that is not thinner than the main artery, sacrificing it should be avoided.[16] The VA needs to be protected during the drilling of the medial and superior portion of the C2 isthmus, which is usually small in pediatric cases. The transverse foramen of C2 may be medial with intraosseous proximal VA and may have a more medial course. The medial portion of the transverse foramen can be dissected, and a fine dissector can be used to protect VA by keeping it medially during insertion of the C2 pedicle screw.[17] Excessive C1–C2 distraction may stretch the VA, injuring its endothelium and leading to dissection with thrombus formation and brainstem infarction. This brainstem infarct may be revealed in a delayed fashion on the second or third postoperative days, so it may be wise to start anticoagulation in cases of excessive handling of the VA.[16] In another article by Salunkhe P et al.,[18] out of 15 patients operated on congenital atlantoaxial dislocation, 10 patients had VA anomalies of different types, and the initial three patients, including one pediatric patient (9-year-old female), underwent sublaminar wiring only. Harvesting Posterior Iliac Crest Graft It can be harvested from the safe zone shown in Figure 3 to prevent injury to the sacroiliac joint medially and superior cluneal nerves laterally, which can cause cluneal neuralgia or loss of sensations over the ipsilateral superior two-thirds of buttock and superior gluteal neurovascular bundle inferiorly. Skin incision can be given in a curvilinear fashion for 5–6 cm starting from Posterior Superior Iliac Spine (PSIS) along the iliac crest, which can be palpated.Figure 3: Safe zone for harvesting posterior iliac crest graft. PSIS – posterior superior iliac spineConclusion An individualized combination of the different surgical strategies must be tailored according to the pathoanatomy of complex CVJ anomalies. A combination of safer wiring techniques with unilateral screw rod fixation for added rotational stability is a viable strategy in cases with the anomalous course of the VA. Patient’s consent Written informed consent has been taken from parents. The patient’s identity has been adequately anonymized. If anything related to the patient’s identity is shown, adequate consent has been taken from the patient’s guardian. The journal will not be responsible for any medicolegal issues arising from issues related to the patient’s identity or any other issues arising from the public display of the video. Financial support and sponsorship Nil. Conflicts of interest There are no conflicts of interest.
No takes yet. Share an insight, caveat, or question.
Sawant et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: