Although VAC dressing system is a very reliable and effective way to support wound healing there are not many mentions in the literature that investigate the use of the VAC system over free flaps, especially for the reconstruction of injuries in the extremities. In this case report we present the use of the VAC system over a mascolocutaneous latissimus dorsi(LD) that was was used to cover the extensive deficits on the left foot after a car accident. In this case the LD flap that was applied showed signs of venous congestion and even though venous re-anastomosis of the flap was used by inter-positioning a vein graft from the contra-lateral leg, still venous congestion was not resolved due to the increased interstitial pressure. With the low negative pressure provided by the VAC system, we managed to overcome the interstitial pressure and achieve adequate capillary perfusion and blood supply to the flap.
No takes yet. Share an insight, caveat, or question.
Sapountzis et al. (2018) studied this question.