Key result
Non-ischemic heart disease was associated with a higher rate of inadequate defibrillation safety margins compared to ischemic heart disease.
Why the study?
Do risk factors for inadequate defibrillation safety margins differ between patients with ischemic and non-ischemic heart disease?
Cohort (n=785)
No
Do risk factors for inadequate defibrillation safety margins differ between patients with ischemic and non-ischemic heart disease?
Risk factors for inadequate defibrillation safety margins, such as younger age and left ventricular dilatation, are specific to patients with non-ischemic heart disease, which could inform selective testing strategies.
Answers are grounded in this paper and cite their sources.
May inform selective DSM testing decisions by etiology; extends prior models by showing predictors apply mainly in non-IHD.
INTRODUCTION: In view of the shift from routine toward no or selective defibrillation testing, optimization of the current risk stratification for inadequate defibrillation safety margins (DSMs) could improve individualized testing decisions. Given the pathophysiological differences in myocardial substrate between ischemic and nonischemic heart disease (IHD/non-IHD) and the accompanying differences in clinical characteristics, we studied inadequate DSMs and their predictors in relation to the underlying etiology. METHODS AND RESULTS: Cohort of routine defibrillation tests (n = 785) after first implantable cardioverter defibrillator (ICD)-implantations at the Radboud UMC (2005-2014). A defibrillation threshold >25 J was regarded as an inadequate DSM. In total, 4.3% of patients had an inadequate DSM; in IHD 2.5% versus 7.3% in non-IHD (P = 0.002). We identified a group of non-IHD patients at high risk (13-42% inadequate DSM); the remainder of the cohort (>70%) had a risk of only 2% (C-statistic entire cohort 0.74; C-statistic non-IHD 0.82). This was based upon two identified interaction terms: (1) non-IHD and age (aOR 0.94 [95% CI 0.91-0.97]); (2) non-IHD and the indexed left ventricular (LV) internal diastolic diameter (aOR 3.50 [95% CI 2.10-5.82]). CONCLUSION: The present study on risk stratification for an inadequate DSM not only confirms the importance of making a distinction between IHD and non-IHD, but also shows that risk factors in an entire cohort (LV dilatation, age) may only apply to a subgroup (non-IHD). Appreciation of this concept could favorably affect current risk stratification. If confirmed, our approach may be used to optimize individualized testing decisions in an upcoming era of non-routine testing.
No takes yet. Share an insight, caveat, or question.
Bonnes et al. (2016) conducted a cohort in First implantable cardioverter defibrillator (ICD) implantation (n=785). Non-ischemic heart disease vs. Ischemic heart disease was evaluated on Inadequate defibrillation safety margin (defibrillation threshold >25 J) (p=0.002). Non-ischemic heart disease was associated with a higher rate of inadequate defibrillation safety margins compared to ischemic heart disease.
Synapse has enriched 10 related papers. Consider them for comparative context: