Case Report (n=1)
No
Capnography can serve as a vital monitoring tool to detect critical perfusion abnormalities such as differential lung perfusion in patients with pulmonary artery stenosis.
Answers are grounded in this paper and cite their sources.
Variable capnograms may flag differential perfusion in repaired TOF; leaves open whether this refines monitoring or requires prospective validation.
Capnography is a simple non-invasive monitoring technique that provides prompt and valuable information about patient's ventilation, perfusion and metabolism. We are presenting a case of a 10 year-old boy with a history of repaired Tetralogy of Fallot (TOF) undergoing a cardiac catheterization for recurrent left pulmonary artery (LPA) stenosis. A variable plateau capnogram waverform was detected and attributed to ventilation-perfusion abnormalities from differential lung perfusion secondary to critical LPA stenosis. Capnogram can prove vital monitoring tool in detecting critical perfusion abnormalities.
No takes yet. Share an insight, caveat, or question.
Surendrasingh Chhabada (2020) conducted a case report in Critical Unilateral Pulmonary Artery Stenosis (n=1). Left pulmonary artery balloon angioplasty and stent placement was evaluated on Capnogram waveform normalization.