Answers are grounded in this paper and cite their sources.
Background Hematomas, rich in platelet-derived growth factors, are vital in tendon-bone healing. Reportedly, larger hematoma-like tissue (HLT) surrounding the repaired tissue at 6–8 weeks after rotator cuff repair on T2-weighted magnetic resonance imaging (MRI) effectively predicts structural outcomes (Sugaya's classification type 1) at 6 months postoperatively. Recent studies explored the use of a reconstituted type I bovine collagen bioinductive implant derived from the bovine Achilles tendon to improve healing rates and tissue thickness, leading to favorable clinical outcomes. Therefore, we aimed to evaluate whether using this collagen implant to cover the lateral side of the sutured rotator cuff enhances the HLT size, formation, and maintenance at 6–8 weeks postoperatively. Methods In this retrospective cohort study, we analyzed patients who underwent arthroscopic rotator cuff repair (ARCR) using the surface-holding (SH) method. Fifty-eight patients were treated without implants (H group), while 58 received bioinductive collagen implants (REGENETEN; Smith & Nephew, Andover, MA, USA ) (R group). MRI was performed at 1 week and 6–8 weeks postoperatively to evaluate HLT thickness, classified as grades 1 (no HLT), 2 (HLT not exceeding the line connecting the cuff surface and the lateral edge of the greater tuberosity), or 3 (HLT exceeding the line). Retears at 6–8 weeks postoperatively were also assessed. Results At 1 week postoperatively, 55.2% of the H group and 60.3% of the R group were classified as grade 3, with no significant difference (p=.71). At 6–8 weeks, 22.4% and 63.8% of the H and R groups, respectively, were classified as grade 3 (p<.05). Moreover, 40.6% and 77.1% of the H and R groups, respectively, maintained grade 3 from week 1 to 6–8 weeks postoperatively (p<.05). In addition, in the H group, no case changed from grade 1 or 2 to grade 3, whereas 37.5% of cases in the R group changed from grade 1 to grade 3 and 50% changed from grade 2 to grade 3. Furthermore, the R group had fewer cases in which the HLT became thinner, disappeared, or experienced a retear compared to the H group (p<.05). Conclusion Implanting a reconstituted type I bovine collagen bioinductive implant in ARCR using the SH method helps to preserve and enhance HLT thickness, with a higher proportion of patients achieving grade 3 HLT at 6–8 weeks postoperatively. These findings suggest the potential of collagen implants to improve tendon-bone healing and structural outcomes.
No takes yet. Share an insight, caveat, or question.
Kinjo et al. (2026) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: