This is the authors' abstract. We don't add key points for this paper.
Background: Effects of rigid posterior instrumentation on the three-dimensional post-operative spinal flexibility are widely unknown. Purpose of this in vitro study was to quantify these effects for characteristic adolescent idiopathic scoliosis instrumentations. Methods: Six fresh frozen human thoracic and lumbar spine specimens (C7-S) with entire rib cage from young adult donors (26-45 years) without clinically relevant deformity were loaded quasi-statically with pure moments of 5 Nm in flexion/extension, lateral bending, and axial rotation. Primary and coupled motions of all segments were measured using optical motion tracking. Specimens were tested without instrumentation and with posterior rod instrumentations ranging from T2 to L1 (for Lenke Type 2) and from T8 to L3 (for Lenke Type 5) based on survey results among spinal deformity surgeons. Statistical differences were evaluated using the pairwise Friedman test. Conclusions: Instrumentation reduces the primary flexibility and diminishes the natural coupling behavior between lateral bending and axial rotation, primarily in the upper thoracic spine, potentially causing correction loss and junctional deformity in the long-term.
Answers are grounded in this paper and cite their sources.
No takes yet. Share an insight, caveat, or question.
Liebsch et al. (2024) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: