Key result
A low magnesium dialysate bath (0.6 mg/dL) did not significantly impact the mean change in QTc dispersion compared to normal magnesium dialysate (9.5 ms vs 9.3 ms) in hemodialysis patients.
Why the study?
Does low magnesium dialysate compared to normal magnesium dialysate affect QTc dispersion in stable hemodialysis patients?
Does low magnesium dialysate compared to normal magnesium dialysate affect QTc dispersion in stable hemodialysis patients?
Using a low magnesium dialysate bath in hemodynamically stable hemodialysis patients does not significantly impact QTc dispersion compared to normal magnesium dialysate.
Answers are grounded in this paper and cite their sources.
Low-magnesium dialysate does not alter QTc dispersion in stable hemodialysis; hypothesis-generating and requires prospective trials before practice change.
BACKGROUND: Electrolyte changes during dialysis affect corrected QT (QTc) and QTc dispersion (QTcd), a surrogate marker of arrhythmogenicity. The impact of magnesium on QTcd is not clear. METHODS: Twenty-two stable patients on maintenance hemodialysis were enrolled in this study. Each underwent two consecutive hemodialysis sessions at least 2 days apart, the first against normal magnesium dialysate (with magnesium at 1.8 mg/dL) followed by a low magnesium dialysate (with magnesium at 0.6 mg/dL). Pre- and post-dialysis weights, blood pressure, electrolytes, and 12-lead surface EKG were recorded. The QT interval and the QTcd were calculated before and after dialysis in both sessions. RESULTS: Of 22 patients, 16 were female. The mean age ± SD was 53.7 ± 18.0 years. The mean change of QTcd (pre- vs. post-dialysis) was 9.5 ms (p = 0.120) and 9.3 ms (p = 0.145) in low and normal magnesium groups, respectively. Using univariate analysis, there was a statistically significant decrease in the mean blood pressure, weight, potassium, magnesium, and QTc interval post-dialysis (compared to pre-dialysis) in both groups (p ≤ 0.049). Post-dialysis concentrations of sodium and calcium were unchanged (compared to pre-dialysis) but bicarbonate increased with both dialysate groups (p < 0.001). The mean change of QTcd was not significant pre- versus post-dialysis by univariate analysis in either group. Multiple linear regression analysis adjusting for pertinent factors did not change the results in either of the two groups. CONCLUSION: Using a low magnesium dialysate bath in hemodynamically stable hemodialysis patients without preexisting advanced cardiac disease does not significantly impact QTcd.
No takes yet. Share an insight, caveat, or question.
Afshinnia et al. (2012) studied Maintenance hemodialysis (n=22). Low magnesium dialysate vs. Normal magnesium dialysate (1.8 mg/dL) was evaluated on Mean change of QTcd (pre- vs. post-dialysis). A low magnesium dialysate bath (0.6 mg/dL) did not significantly impact the mean change in QTc dispersion compared to normal magnesium dialysate (9.5 ms vs 9.3 ms) in hemodialysis patients.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: