Key result
Insufficient ICD knowledge is linked to ~28-point higher rates of mild cognitive impairment.
Why the study?
Is insufficient implantable cardioverter defibrillator (ICD) knowledge associated with patient characteristics (such as cognitive impairment and age) and unwillingness to discuss end-of-life device deactivation in ICD recipients?
Cross-Sectional (n=270)
Yes
Is insufficient implantable cardioverter defibrillator (ICD) knowledge associated with patient characteristics (such as cognitive impairment and age) and unwillingness to discuss end-of-life device deactivation in ICD recipients?
Nearly one-third of ICD recipients have insufficient knowledge regarding device function and end-of-life deactivation—particularly older adults and those with mild cognitive impairment—which is associated with reluctance to discuss device deactivation near the end of life.
Answers are grounded in this paper and cite their sources.
May warrant cognitive assessment to address ICD knowledge gaps in older recipients; leaves open effects on end-of-life deactivation discussions.
BACKGROUND: End-of-life implantable cardioverter defibrillator deactivation discussions should commence before device implantation and be ongoing, yet many implantable cardioverter defibrillators remain active in patients' last days. AIM: To examine associations among implantable cardioverter defibrillator knowledge, patient characteristics and attitudes to implantable cardioverter defibrillator deactivation. DESIGN: Cross-sectional survey using the Experiences, Attitudes and Knowledge of End-of-Life Issues in Implantable Cardioverter Defibrillator Patients Questionnaire. Participants were classified as insufficient or sufficient implantable cardioverter defibrillator knowledge and the two groups were compared. SETTING/PARTICIPANTS: Implantable cardioverter defibrillator recipients ( n = 270, mean age 61 ± 14 years; 73% male) were recruited from cardiology and implantable cardioverter defibrillator clinics attached to two tertiary hospitals in Melbourne, Australia, and two in Kentucky, the United States. RESULTS: Participants with insufficient implantable cardioverter defibrillator knowledge ( n = 77, 29%) were significantly older (mean age 66 vs 60 years, p = 0.001), less likely to be Caucasian (77% vs 87%, p = 0.047), less likely to have received implantable cardioverter defibrillator shocks (26% vs 40%, p = 0.031), and more likely to have indications of mild cognitive impairment (Montreal Cognitive Assessment score <24: 44% vs 16%, p < 0.001). Insufficient implantable cardioverter defibrillator knowledge was associated with attitudes suggesting unwillingness to discuss implantable cardioverter defibrillator deactivation, even during the last days towards end of life ( p < 0.05). CONCLUSION: Implantable cardioverter defibrillator recipients, especially those who are older or have mild cognitive impairment, often have limited knowledge about implantable cardioverter defibrillator deactivation. This study identified several potential teachable moments throughout the patients' treatment trajectory. An interdisciplinary approach is required to ensure that discussions about implantable cardioverter defibrillator deactivation issues are initiated at appropriate time points, with family members ideally also included.
No takes yet. Share an insight, caveat, or question.
McEvedy et al. (2017) conducted a cross-sectional in Implantable cardioverter defibrillator (ICD) recipients (n=270). Insufficient implantable cardioverter defibrillator knowledge (EOL-ICDQ score <=4 out of 11) vs. Sufficient implantable cardioverter defibrillator knowledge (EOL-ICDQ score >4 out of 11) was evaluated on Indication of mild cognitive impairment (Montreal Cognitive Assessment score <24) (p=<0.001). Insufficient ICD knowledge was present in 29% of recipients and was associated with mild cognitive impairment and older age.