Answers are grounded in this paper and cite their sources.
A method for the determination of dimethyl fumarate (DMF) in desiccant and antimould sachets, employed for protecting consumer products from humidity and mould, has been developed. The method is based on a solid-liquid extraction followed by HPLC-UV analysis. The method was validated with respect to recovery, linearity, limits of detection and quantitation and precision. The recovery was 98%. The correlation coefficient value (r) was equal to 0.94. Both intra- and inter-day precisions were studied at several concentration levels, being satisfactory in all cases (RSD < 5). Limits of detection and quantification values were in the low microgram per gram level, thus allowing the determination of DMF at concentrations below the limit established (0.1 mg/kg) by the recent EU Directive (Decision 2009/251/EC). The proposed procedure was applied for the determination of the target compound in 41 desiccant and antimould samples. DMF was detected in 39.0% of samples and its content in many samples exceeded the legal limits. The results of our analysis highlight the high risk of exposure to this powerful allergic sensitizer for consumers.
No takes yet. Share an insight, caveat, or question.
Gennari et al. (2011) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: