New power spectra computed from LDA measurements of the fluctuating u- and v-velocity signals in a turbulent channel flow with and without drag-reducing polymer (polyethylene oxide) injection are presented. LDA data rates were sufficiently high to reconstruct the simultaneous time-dependent u- and v-velocity signals along with the time-dependent Reynolds stress signal. Time-averaged statistics of the turbulent flow are presented in conjunction with the power spectral measurements which show a dramatic reduction in both the v-velocity fluctuations and Reynolds stress fluctuations throughout the channel over all frequencies. There is also a redistribution of energy in the u-velocity fluctuations from high frequencies to low frequencies throughout the channel. Different injection conditions were examined: different polymer concentrations were injected at different flow rates such that the total amount of polymer in the channel remained constant. For certain polymer concentrations, ‘large’ negative Reynolds stress, -〈uv〉/uτ2 ≈ − 0.2, was measured in the near-wall region. In addition, there is a marked difference in the u-velocity spectra and the Reynolds stress spectra close to the wall for the different injection conditions.
No takes yet. Share an insight, caveat, or question.
Wei et al. (1992) studied this question.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: