Key result
Arthroscopic labral repair using all-suture anchors resulted in no recurrent instability or hardware complications at a mean 30-month follow-up, with 82% of implants showing no bone alteration.
Why the study?
The study evaluated radiological and clinical outcomes in patients with glenohumeral instability or SLAP lesions treated by arthroscopic repair using all-suture anchors.
Does arthroscopic repair using all-suture anchors improve clinical and radiological outcomes in patients with glenohumeral instability or SLAP lesions?
Observational (n=54)
No
Does arthroscopic repair using all-suture anchors improve clinical and radiological outcomes in patients with glenohumeral instability or SLAP lesions?
Arthroscopic repair with all-suture anchors for glenohumeral instability or SLAP lesions is safe and effective, with good clinical outcomes and minimal bone reaction at short- to mid-term follow-up.
Hypothesis-generating for all-suture anchors in labral repair; leaves open need for comparative trials before practice change.
Aim To evaluate radiological and clinical outcomes of a case series of patients affected by glenohumeral instability (Bankart lesion) or superior labrum tear from anterior to posterior (SLAP) lesions treated by arthroscopic repair using all-suture anchors. Methods Patients were operated by a single surgeon at a single Institution. Exclusion criteria were chondral lesions of the glenoid, rotator cuff lesions, previous surgery at the index shoulder, or a bony Bankart lesion. Position and numbers of anchors used depended on the dimension and type of lesion. The DASH (Disability of the Arm, Shoulder and Hand) and Constant scores were used for subjective and clinical evaluation at follow-ups (FUs); also, at 1-year FU, MRI scan was obtained to evaluate bone reaction to the implanted devices. Results Fifty-four patients were included. A mean of 2.7 devices per patient (145 in total) were implanted. Mean FU was 30 (range 12 - 48) months. No patient reported recurrent instability, nor hardware-related complications were registered. MRI analyses showed that 119 (82%) implants did not alter surrounding bone (grade 0), 26 (18%) implants were surrounded by bone oedema (grade 1), while no bone tunnel enlargement nor a bone cyst (grade 2 or 3, respectively) were registered. Conclusion This study confirmed the efficacy and safety of a specific all-suture anchor system in the arthroscopic repair of the glenoid labrum for glenohumeral instability or a SLAP lesion. In the short- and mid-term period, these devices were associated with good clinical and radiological outcomes without clinical failures or reaction at bone-device interface.
No takes yet. Share an insight, caveat, or question.
Sacchetti et al. (2020) conducted an observational in Glenohumeral instability (Bankart lesion) or superior labrum tear from anterior to posterior (SLAP) lesions (n=54). Arthroscopic repair using all-suture anchors was evaluated on Recurrent instability, hardware-related complications, and bone reaction on MRI. Arthroscopic labral repair using all-suture anchors resulted in no recurrent instability or hardware complications at a mean 30-month follow-up, with 82% of implants showing no bone alteration.