Key result
After an arterial switch operation, exercise capacity is reduced but left ventricular ejection fraction is preserved.
Why the study?
Does the arterial switch operation for transposition of the great arteries result in preserved long-term exercise capacity and left ventricular function compared with healthy controls?
Meta-Analysis
Does the arterial switch operation for transposition of the great arteries result in preserved long-term exercise capacity and left ventricular function compared with healthy controls?
Long-term follow-up after arterial switch operation for transposition of the great arteries demonstrates preserved left ventricular ejection fraction but reduced exercise capacity.
Answers are grounded in this paper and cite their sources.
Reduced exercise capacity despite preserved LVEF after arterial switch warrants monitoring; confirms LV preservation but challenges assumptions of normal functional recovery.
BACKGROUND: The arterial switch operation for transposition of the great arteries was initially believed to be an anatomical correction. Recent evidence shows reduced exercise capacity and left ventricular function in varying degrees in the long term after an arterial switch operation. OBJECTIVE: To perform a meta-analysis on long-term exercise capacity and left ventricular ejection fraction after an arterial switch operation. METHODS: A literature search was performed to cover all studies on patients who had undergone a minimum of 6 years of follow-up that reported either left ventricular ejection fraction, peak oxygen uptake, peak workload, and/or peak heart rate. A meta-analysis was performed if more than three studies reported the outcome of interest. RESULTS: A total of 21 studies reported on the outcomes of interest. Oxygen uptake was consistently lower in patients who had undergone an arterial switch operation compared with healthy controls, with a pooled average peak oxygen uptake of 87.5±2.9% of predicted. The peak heart rate was also lower compared with that of controls, at 92±2% of predicted. Peak workload was significantly reduced in two studies. Pooled left ventricular ejection fraction was normal at 60.7±7.2%. CONCLUSION: Exercise capacity is reduced and left ventricular ejection fraction is preserved in the long term after an arterial switch operation for transposition of the great arteries.
No takes yet. Share an insight, caveat, or question.
Wijk et al. (2018) conducted a meta-analysis in Transposition of the great arteries. Arterial switch operation vs. Healthy controls was evaluated on Long-term exercise capacity and left ventricular ejection fraction. After an arterial switch operation, exercise capacity is reduced but left ventricular ejection fraction is preserved.
Synapse has enriched 10 related papers. Consider them for comparative context: