Answers are grounded in this paper and cite their sources.
A patient with keratoconus had cataract extraction and intraocular lens (IOL) implantation in both eyes. The IOL power was determined using keratometric values (K-values) measured by standard keratometry in the right eye and videokeratography in the left eye. The ideal IOL power and the K-value that would have led to the ideal IOL power were determined from the postoperative refraction at 6 weeks. The ideal K-value was compared with the K-values derived from videokeratography and standard keratometry. Refraction at 6 weeks postoperatively was 5.60 and 1.00 diopter more myopic than the aim in the right and left eye, respectively. The mean power in ring 3 in videokeratography of the left eye was the same as the ideal K-value calculated using the Holladay formula. Determining IOL powers with videokeratography-derived K-values might be more accurate than standard keratometry in patients with keratoconus.
No takes yet. Share an insight, caveat, or question.
CELIKKOL et al. (1996) studied this question.
Synapse has enriched 10 related papers. Consider them for comparative context: