Answers are grounded in this paper and cite their sources.
Ixabepilone (BMS-247550, Ixempra is a semi-synthetic analog of the natural product epothilone B and marketed for its use in the treatment of cancer. A conventional human ADME study using decay counting methods for (14)C detection could not be conducted due to the radiolytic instability of [(14)C]ixabepilone at a typical specific activity (generally 1-10 microCi/mg). However, [(14)C]ixabepilone was sufficiently stable at low specific activity (1-2 nCi/mg). These low levels required the use of accelerator mass spectrometry (AMS) for radioactivity detection. The metabolic fate of this compound was investigated in eight patients following single intravenous doses of [(14)C]ixabepilone (70 mg, 80 nCi; specific activity: 1.14 nCi/mg). Metabolite profiles in pooled urine, feces and plasma samples were determined by HPLC-AMS analysis. The major radioactive component in urine and plasma was [(14)C]ixabepilone. Feces had a small amount of ixabepilone. There were numerous other drug-related components in both urine and fecal extracts (each <6% of the administered dose). LC/MS analysis of plasma, urine and feces samples showed the presence of three degradants of ixabepilone and several oxidative metabolites (M+16, M+14 and M-2 metabolites). This study demonstrates the utility of AMS in investigating the metabolite and excretion profiles of [(14)C]ixabepilone following administration to humans.
No takes yet. Share an insight, caveat, or question.
Çömezoğlu et al. (2009) studied this question.