Answers are grounded in this paper and cite their sources.
Investigations of the effects of surface roughness on the utility of grazing-angle Fourier transform infrared reflection absorption spectroscopy (IRRAS) as a method for quantifying trace contamination of metal surfaces have been extended to acetaminophen, a model active pharmaceutical agent, on 316 stainless steel. The effects are more complicated than for the surfactant sodium dodecyl sulfate (SDS) on stainless steel; they include a strong surface-finish dependence of sensitivity and nonlinear behavior at surface loadings above approximately 1-2 microg cm(-2). Using data from samples in the loading range 0-0.5 microg cm(-2), unbiased partial least squared calibrations can be readily achieved for individual surface finishes with detection limits of L(D) approximately 0.15 microg cm(-2). However, as found for SDS on stainless steel, models built using data from samples of mixed surface roughness are more problematic.
No takes yet. Share an insight, caveat, or question.
Perston et al. (2008) studied this question.