Key result
Novel EWT-WT algorithm outperforms standard methods for ECG motion artifact removal and signal restoration.
Why the study?
Clean ECG signals are critical for analyzing and diagnosing heart diseases, but recordings in non-contact ECG monitoring systems are often contaminated by motion artifact noise.
Does an adaptive motion artifact removal method based on empirical wavelet transform and wavelet thresholding (EWT-WT) improve ECG signal quality and reduce distortion compared to DWT, EMD, and EWT methods in simulated and non-contact ECG recordings?
Does an adaptive motion artifact removal method based on empirical wavelet transform and wavelet thresholding (EWT-WT) improve ECG signal quality and reduce distortion compared to DWT, EMD, and EWT methods in simulated and non-contact ECG recordings?
The proposed EWT-WT signal processing algorithm effectively removes motion artifacts while preserving QRS complex morphology in non-contact capacitive ECG monitoring systems.
Answers are grounded in this paper and cite their sources.
EWT-WT may aid non-contact ECG monitoring; hypothesis-generating and requires prospective clinical validation before adoption.
Electrocardiogram (ECG) signals are crucial for determining the health status of the human heart. A clean ECG signal is critical in analysis and diagnosis of heart diseases. However, ECG signals are often contaminated by motion artifact noise in the non-contact ECG monitoring systems. In this paper, an ECG motion artifact removal approach based on empirical wavelet transform (EWT) and wavelet thresholding (WT) is proposed. This method consists of five steps, namely, spectrum preprocessing, spectrum segmentation, EWT decomposition, wavelet threshold denoising, and EWT reconstruction. The proposed approach was used to process real ECG signals collected by the non-contact ECG monitoring equipment. The results of quantitative study and analysis indicate that this approach produces a better performance in terms of restorage of QRS complexes of the original ECG with reduced distortion, retaining useful information in ECG signals, and improvement of the signal to noise ratio (SNR) value of the signal. The output results of the practical ECG signal test show that motion artifact in the real recorded ECG is effectively filtered out. The proposed method is feasible for reducing motion artifacts from ECG signals, whether from simulation ECG signals or practical non-contact ECG monitoring systems.
No takes yet. Share an insight, caveat, or question.
Xu et al. (2019) studied ECG motion artifact in non-contact ECG monitoring systems (n=3). Empirical wavelet transform and wavelet thresholding (EWT-WT) motion artifact removal algorithm vs. Discrete wavelet transform (DWT), empirical mode decomposition (EMD), and empirical wavelet transform (EWT) denoising methods was evaluated on Signal restoration and denoising performance measured by correlation coefficient (Corr), mean square error (MSE), percentage root mean square difference (PRD), and output signal-to-noise ratio improvement (SNRimp). Empirical wavelet transform and wavelet thresholding (EWT-WT) outperformed DWT, EMD, and EWT methods in MSE, PRD, correlation coefficient, and SNR improvement for ECG motion artifact removal.
Synapse has enriched 10 related papers. Consider them for comparative context: