Key result
RVSS APA active noise cancellation boosts capacitive ECG R-peak detection accuracy by up to ~8 percentage points.
Why the study?
Does active noise cancellation using a robust variable step size affine projection sign algorithm (RVSS APA) improve R peak detection accuracy in capacitive ECG recordings compared to conventional affine projection algorithm (APA) filtering during motion and driving?
Does active noise cancellation using a robust variable step size affine projection sign algorithm (RVSS APA) improve R peak detection accuracy in capacitive ECG recordings compared to conventional affine projection algorithm (APA) filtering during motion and driving?
Answers are grounded in this paper and cite their sources.
Treating the QRS complex as impulsive noise within a robust variable step size adaptive filter conserves QRS power while suppressing motion artifacts, improving R peak detection in non-contact capacitive ECG sensors during daily movement and driving.
Electrocardiograms (ECGs) can be conveniently obtained using capacitive ECG sensors. However, motion noise in measured ECGs can degrade R peak detection. To reduce noise, properties of reference signal and ECG measured by the sensors are analyzed and a new method of active noise cancellation (ANC) is proposed in this study. In the proposed algorithm, the original ECG signal at QRS interval is regarded as impulsive noise because the adaptive filter updates its weight as if impulsive noise is added. As the proposed algorithm does not affect impulsive noise, the original signal is not reduced during ANC. Therefore, the proposed algorithm can conserve the power of the original signal within the QRS interval and reduce only the power of noise at other intervals. The proposed algorithm was verified through comparisons with recent research using data from both indoor and outdoor experiments. The proposed algorithm will benefit a noise reduction of noisy biomedical signal measured from sensors.
No takes yet. Share an insight, caveat, or question.
Seo et al. (2018) studied Healthy volunteers undergoing capacitive ECG monitoring during indoor movement and outdoor driving (n=29). Active noise cancellation (ANC) using robust variable step size affine projection sign algorithm (RVSS APA) vs. Conventional ANC using affine projection algorithm (APA) and raw measured capacitive ECG was evaluated on Average R peak detection performance (Avg), defined as the mean of sensitivity (Se) and positive predictivity (P+). Active noise cancellation using RVSS APA increased average R peak detection accuracy by 8.22% indoors and 6.28% outdoors compared to raw capacitive ECG, outperforming standard APA.
Synapse has enriched 10 related papers. Consider them for comparative context: