A computer program for modeling ammonia (NH3) re-lease in broiler houses has been developed. The model estimated that during the first weeks for flocks grown on reused litter, NH3 concentrations can reach 200-300 ppm; safe levels (<25 ppm) require ventilation rates ten times normal. Of the factors studied, the order of importance in influencing NH3 volatilization was: lit-ter pH temperature > moisture content.