Answers are grounded in this paper and cite their sources.
This paper describes a new partial‐discharge detection method for an XLPE‐insulated copper wire‐shielded cable line using a “yoke coil.” Partial discharges are measured with the yoke coil which detects the azimuthal component of the current flowing through the copper wires wound on an outer semiconducting layer with a given angle against the axial direction of the cable. The highest detection sensitivity of 2 pC has been achieved at a frequency range of 5 to 20 MHz using a 77‐kV 100‐mm2 model cable line (200 m in length). It was confirmed that the partial discharge caused by an artificial defect has successfully been detected using the proposed method. In the PD measurement for an actual 77‐kV XLPE‐insulated live line, the detection sensitivity was 10 pC.
No takes yet. Share an insight, caveat, or question.
Nakanishi et al. (1993) studied this question.