Key result
Anticoagulation with warfarin and heparin in a patient with a prosthetic aortic valve resulted in 3 intracranial bleeds, illustrating the challenge of balancing bleeding and thromboembolic risks.
Case Report (n=1)
Highlights the clinical dilemma of balancing thromboembolic risk against further bleeding when managing anticoagulation in patients with mechanical heart valves who experience intracranial haemorrhage.
Answers are grounded in this paper and cite their sources.
Underscores individualized anticoagulation decisions after ICH in mechanical valve patients; leaves open optimal regimens for prospective trials.
Mechanical heart valves are associated with a risk of thromboembolism and anticoagulation is generally recommended. However, this is inevitably associated with a risk of intracranial bleeding. The case of a patient who sustained an intracranial bleed while taking warfarin for a prosthetic aortic valve and a further two intracranial bleeds while on heparin as an inpatient is discussed and the literature on the management of intracranial haemorrhage in patients on warfarin with prosthetic valves is reviewed.
No takes yet. Share an insight, caveat, or question.
F Crawley (2000) conducted a case report in Intracranial bleeding associated with anticoagulation for prosthetic heart valves (n=1). Anticoagulation (warfarin and heparin) was evaluated. Anticoagulation with warfarin and heparin in a patient with a prosthetic aortic valve resulted in 3 intracranial bleeds, illustrating the challenge of balancing bleeding and thromboembolic risks.