Key result
Miniaturized CPB significantly reduced the inflammatory response compared to standard CPB in aortic valve surgery, with lower post-CPB levels of elastase (116 vs 265 ng/ml, P=0.01).
Why the study?
Does a miniaturized CPB circuit reduce the systemic inflammatory response compared to a standard CPB circuit in patients undergoing singular aortic valve replacement?
Population
40 patients undergoing singular aortic valve replacement
Comparison
Miniaturized cardiopulmonary bypass (CPB) circuit vs Standard cardiopulmonary bypass (CPB) circuit
Design
RCT, randomly assigned
Follow-up
post-CPB
Authors
Loading...
Supports miniaturized CPB in AVR to limit inflammation; confirms benefit in an RCT.
RCT (n=40)
randomly assigned
Does a miniaturized CPB circuit reduce the systemic inflammatory response compared to a standard CPB circuit in patients undergoing singular aortic valve replacement?
p-value: p=0.01
Miniaturized CPB circuits attenuate the systemic inflammatory response compared to standard circuits during aortic valve replacement.
Bical et al. (2006) conducted an RCT in singular aortic valve replacement (n=40). Miniaturized CPB circuit vs. Standard CPB circuit was evaluated on Systemic inflammatory response (neutrophil elastase) (p=0.01). Miniaturized CPB significantly reduced the inflammatory response compared to standard CPB in aortic valve surgery, with lower post-CPB levels of elastase (116 vs 265 ng/ml, P=0.01).