Key result
A clinical monitoring system for centrifugal blood pumps detected suction events in >95% of cases in a mock circulation and >90% of events during in vivo application.
Why the study?
Does a software-based clinical monitoring system reliably detect suction events in centrifugal blood pumps?
Does a software-based clinical monitoring system reliably detect suction events in centrifugal blood pumps?
A newly developed software monitoring system for centrifugal blood pumps reliably detects suction events in both mock circulation and in vivo settings, potentially improving device safety.
Answers are grounded in this paper and cite their sources.
May support suction monitoring in centrifugal pumps; leaves open human validation before clinical adoption.
In clinical application of rotary blood pumps, flow obstruction as a result of suction of the inflow cannula, kinking of tubing, or thrombus formation occurs quite frequently. Early detection of such problems is essential to avoid hemolysis, tissue degradation, or release of thrombi to the patient. A program was developed for automatic observation of pump performance, tubing resistance, and suction effects, which requires only the measurement of already available parameters (i.e., pump speed, pump flow, aortic pressure). The software is based on Visual-C and provides a user surface formatted in Windows. Pump flow, its time derivate, and the relationship between the pulsatile component and the mean graft flow are observed to detect suction in the left atrium. Furthermore, the generated pressure head is predicted from pump speed, graft flow, and the resistance of tubing/cannula and compared with the actually measured aortic pressure. An alarm sounds if a given limit between prediction and measurement is exceeded. In a mock circulation, suction events were detected in more than 95% with a mean deviation of actual aortic pressure from its predicted value of less than 5%. For in vivo application, even incomplete suction could be detected reliably in more than 90% of events. This system improves and standardizes monitoring of pump performance; it should therefore lead to greater safety during application of such devices.
No takes yet. Share an insight, caveat, or question.
Holzer et al. (1995) studied Rotary blood pump application. Clinical Monitoring System for Centrifugal Blood Pumps was evaluated on Detection of suction events. A clinical monitoring system for centrifugal blood pumps detected suction events in >95% of cases in a mock circulation and >90% of events during in vivo application.
Synapse has enriched 10 related papers. Consider them for comparative context: