Answers are grounded in this paper and cite their sources.
The breakdown strength of air has been determined for alternating electric fields of frequencies between 100 and 300 Mc/s. Parallel plane gaps up to 1 mm wide have been investigated.A description is given of the apparatus employed, together with details of a dielectric voltmeter which has enabled the voltage across the breakdown gap to be measured accurately.A discontinuity is shown to exist in the relation between the breakdown stress and the gap width. The breakdown stress for small gap widths appears to follow a curve representing values some 10–15% below those obtained with direct current. At a critical gap width, which is dependent primarily on the frequency of the applied electric field, there is a sudden decrease in the electric stress at which breakdown occurs, to a constant value, which for atmospheric pressure is 29 kV/cm. The critical gap width is found to vary slightly with gas pressure, and may be increased by the application of a small d.c. electric field across the gap.An examination of the results shows that under transition conditions Paschen's law is not applicable. A theory is put forward on the basis that breakdown may be initiated in one of three different ways, each of which may be represented by a curve that separately obeys Paschen's law.
No takes yet. Share an insight, caveat, or question.
J. A. PIM (1949) studied this question.