A new technique has been developed for measuring small conduction currents due to microsecond duration pulses of voltage; the method is equally applicable to longer duration pulses. It uses a charge-storing technique in which the conduction current through the sample is integrated on a capacitor whose voltage is measured after the high voltage pulse is terminated. The sensitivity of the method can be increased by integrating charge over a large number of pulses. With high voltage pulses as short as 1 μsec, the technique enables one to measure currents of 1 μA with an accuracy of about 5%.