Key result
Standardized brightness-mode ultrasound measurements of subcutaneous adipose tissue in children aged three to six years demonstrated high inter-observer reliability, with an intra-class correlation coefficient of 0.998.
Why the study?
Standardized brightness-mode ultrasound for subcutaneous adipose tissue measurement showed high reliability in adults, but inter-observer reliability needed to be determined in children aged three to six years.
Does standardized brightness-mode ultrasound provide high inter-observer reliability for measuring subcutaneous adipose tissue in children aged 3 to 6 years?
Cross-Sectional (n=20)
Yes
Does standardized brightness-mode ultrasound provide high inter-observer reliability for measuring subcutaneous adipose tissue in children aged 3 to 6 years?
Effect estimate: ICC 0.998 (95% CI 0.980-0.999)
Standardized brightness-mode ultrasound provides highly reliable measurements of subcutaneous adipose tissue in preschool children, comparable to the reliability previously demonstrated in adults.
Background A procedure to measure subcutaneous adipose (SAT) using brightness-mode ultrasound has recently been standardized and applied to various groups of adults including underweight, overweight and obese adults. High reliability of this procedure was found in each of the examined groups. The purpose of this study was to determine inter-observer reliability of the standardized brightness-mode ultrasound measurement of uncompressed SAT in three to six-year-old children. Methods Three experienced observers independently captured the ultrasound images at the eight standardized measurement sites in each of the 20 children and evaluated their images using an interactive software that detects the SAT contour and automatically measures multiple thicknesses in each image; the mean of these represents SAT thickness at a given site. The children were aged 4.9 ± 1.0 years; their body mass index ranged from 13.6–17.7 kgm− 2. Sound speed was set to 1450 ms− 1for SAT. Results SAT thickness sums with fibrous structures included (DI) ranged from 25.7–86.4 mm, meanDIwas 48.1 ± 15.5 mm. ForDI, resulting from 160 measurements by each observer, the intra-class correlation coefficient was 0.998 (95% confidence interval 0.980–0.999), standard error of the estimate was 1.1 mm, and 95% limits of agreement were within ±2.1 mm. The median difference inDIwas 0.8 mm, i.e. about 1.9% of meanDI. Conclusions Inter-observer results in children are comparable to previously described high reliability in adults. This method, which provides a technical thickness measurement accuracy of about 0.1 to 0.2 mm, enables monitoring of subcutaneous adipose tissue in children with a similarly high reliability as was obtained in adults previously. Trial registration German Institute of Medical Documentation and Information, German Clinical Trials Register (DRKS) ID: DRKS00010089 ; Date 24/02/2016.
No takes yet. Share an insight, caveat, or question.
Kelso et al. (2020) conducted a cross-sectional in Healthy preschool children (n=20). Standardized brightness-mode ultrasound measurement of subcutaneous adipose tissue vs. Inter-observer comparison was evaluated on Inter-observer reliability of subcutaneous adipose tissue thickness sums including fibrous structures (DI) (ICC 0.998, 95% CI 0.980-0.999). Standardized brightness-mode ultrasound measurements of subcutaneous adipose tissue in children aged three to six years demonstrated high inter-observer reliability, with an intra-class correlation coefficient of 0.998.