Key result
The Dog Bone Technique for aortic stent implantation achieved targeted positioning in 100% of cases (91 stents in 87 patients) without requiring cardiac output reduction or causing acute complications.
Why the study?
Does the Dog Bone Technique allow safe and feasible stent implantation in patients with aortic arch stenosis or coarctation?
Observational (n=87)
Does the Dog Bone Technique allow safe and feasible stent implantation in patients with aortic arch stenosis or coarctation?
The Dog Bone Technique is a safe and feasible method for aortic stent implantation that avoids the need for adjunctive cardiac output reduction techniques.
BACKGROUND: Various techniques are described to facilitate stable stent implantation in aortic arch stenosis or coarctation. We describe an alternative technique, which due to its unique appearance during stent implantation, we have named "Dog Bone Technique" (DBT). TECHNIQUE: The stent/balloon assembly is placed across the stenosis, the long sheath is retrieved to uncover the distal 20-50% of the stent. The balloon is inflated with the pressure inflator just to expand slightly the stent. Thereafter the sheath is pulled back and the proximal end is uncovered and partially inflated; therewith the assembly takes the typical "dog bone" shape before complete inflation and final positioning. Repositioning of the stent and control angiography is possible at each time of this procedure. RESULTS: Between 1/2010 and 12/2014 we implanted 91 stents in 87 patients (mean age 20.2 years). About 71 patients had native or re-coarctation and 16 patients had transverse aortic arch stenosis. In 38 patients (44%) a pharmacological exercise test with Orciprenaline was performed during implantation resulting in high-cardiac output. In none of the patients reduction of cardiac output by adenosine or a rapid pacing of the right ventricle was required for stable stent implantation. All stents were implanted in the targeted position using this single balloon technique. There were no acute or short-term complications detected. CONCLUSION: DBT is a safe and feasible technique for aortic stent implantation even at high-cardiac output. Other additional techniques for stent placement are not necessary to obtain a stable final position in the target region.
No takes yet. Share an insight, caveat, or question.
Kantzis et al. (2016) conducted an observational in Aortic arch stenosis or coarctation (n=87). Dog Bone Technique (DBT) was evaluated on Successful stent implantation in the targeted position without acute or short-term complications. The Dog Bone Technique for aortic stent implantation achieved targeted positioning in 100% of cases (91 stents in 87 patients) without requiring cardiac output reduction or causing acute complications.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: