Key result
Electronic pacing was used to treat two siblings with familial congenital heart block; the boy survived to age six, while the sister died of complications related to pacemaker size.
Case Report (n=2)
This case series details the clinical course and histopathological findings of familial congenital complete heart block, highlighting specific conduction system abnormalities.
Answers are grounded in this paper and cite their sources.
Early pacing may extend survival in familial congenital heart block despite device size limits; hypothesis-generating for pediatric hardware and timing.
Complete heart block was found shortly after birth in a brother and sister (not twins). Both were treated by electronic pacing because of symptoms attributable to inadequate cardiac output and electrical instability of heart. The boy has done well with his artificial pacemaker and is now six years old. His sister died of complications due in part to the large size of her pacemaker and small size of her body. At necropsy special studies of her heart included the centers for normal impulse formation and concuction. The primary abnormalities were at the junction of atrial septum with atrioventricular (A-V) node, and at the origin of the two bundle branches from the His bundle. The A-V node was isolated by collagen at all its margins except its junction with the His bundle. The proximal His bundle was essentially normal, but from that point on through the initial protions of both the left and right bundle branches there was extensive caseous degeneration which interrupted any possible conduction. These findings are discussed in relation to fetal and postnatal development of the human A-V node, and the His bundle and its branches; and in the context of a recently observed mathematical relationship between sinus rate and two forms of experimentally produced A-V junctional escape rhythms.
No takes yet. Share an insight, caveat, or question.
James et al. (1975) conducted a case report in Familial congenital heart block (n=2). Electronic pacing was evaluated. Electronic pacing was used to treat two siblings with familial congenital heart block; the boy survived to age six, while the sister died of complications related to pacemaker size.