Key result
Careful technique, minimal oversizing, and disease-specific stent grafts may reduce the risk of stent graft-induced new entry tears after TEVAR for type B aortic dissection.
Why the study?
What are the mechanisms, treatments, and prevention strategies for stent-graft induced new entry (SINE) tears after TEVAR for type B aortic dissection?
What are the mechanisms, treatments, and prevention strategies for stent-graft induced new entry (SINE) tears after TEVAR for type B aortic dissection?
Careful technique, minimal oversizing, and disease-specific stent grafts are crucial to prevent potentially fatal stent-graft induced new entry tears after TEVAR for type B aortic dissection.
Supports optimizing TEVAR technique to potentially lower SINE risk; leaves open need for prospective validation in type B dissection.
Progress of aortic disease after stent-graft treatment of aortic dissection includes the risk of stent graft-induced new entry (SINE). In this paper we review the incidence and mechanisms thought to be responsible for retrograde ascending and distal SINE after thoracic endovascular aortic repair (TEVAR) for type B dissection, and examine potential techniques for treatment and prevention. Although the risk of proximal SINE is low, the fatality of this complication requires vigilance in patients who develop new onset symptoms in the early period after TEVAR treatment. Careful technique, minimal oversizing, and use of disease specific stent grafts may reduce the risk for proximal SINE. Distally, SINE is more frequently seen during follow-up in patients treated for chronic dissection. The most important risk factor is oversizing of the stent-graft compared to the true lumen distal landing zone. Development of new disease specific stent grafts with reduced distal radial force may reduce the risk for distal SINE.
No takes yet. Share an insight, caveat, or question.
Burdess et al. (2018) conducted a review in Type B aortic dissection. Thoracic endovascular aortic repair (TEVAR) was evaluated on Incidence and mechanisms of retrograde ascending and distal stent graft-induced new entry (SINE). Careful technique, minimal oversizing, and disease-specific stent grafts may reduce the risk of stent graft-induced new entry tears after TEVAR for type B aortic dissection.
Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context: